With SINUMERIK Integrate Access MyMachine /P2P, the minsys.img file is copied to an empty
replacement card.
Precondition to write:
● SINUMERIK Integrate Access MyMachine /P2P is installed.
● SW package: Configuration data from the Toolbox has been installed.
● CompactFlash card is a replacement card.
Installing the boot system on an empty card
Procedure:
1. Insert the CompactFlash Card into the card reader.
2. Start the program via "Start" → "Programs" → "SINUMERIK" → "Tools" → "Access
MyMachine P2P".
3. Press "Cancel" if you are prompted to establish the connection.
Note
An online connection to the control is not required to generate the boot system.
4. In the ""Options" menu, select the menu item "Write SINUMERIK 828D boot system...":
5. If several versions of the toolbox are installed on the PC, you obtain the following selection:
Software and hardware
Service Manual, 08/2018, 6FC5397-5DP40-6BA1
3.5 Generating a boot system on the CompactFlash card
Service cases - software
57