Siemens SINUMERIK 828D Series Software And Hardware Service Manual page 131

Hide thumbs Also See for SINUMERIK 828D Series:
Table of Contents

Advertisement

Response of the LEDs in operation
LED
Color
RDY
-
(READY)
Green
Red
Red/green
Orange
Green/Or‐
ange
or
Red/Or‐
ange
COM
-
Green
Red
MOD
-
OUT > 5 V
-
Orange
Make sure that the encoder connected is designed for a 24 V supply. Connecting a 5 V encoder to a 24 V supply can
1)
destroy the encoder electronics.
Software and hardware
Service Manual, 08/2018, 6FC5397-5DP40-6BA1
State
Description / cause
Off
Electronics power supply is missing or outside
permissible tolerance range.
Continuous light
The unit is ready for operation.
Cyclic DRIVE-CLiQ communication is in progress.
Flashing light 0.5
Commissioning/reset
Hz
Flashing light 2 Hz
Writing to the memory card.
Flashing light
General error
2 Hz
Flashing light
The Control Unit is ready for operation, but there
0.5 Hz
are no software licenses.
Flashing light
Updating the firmware of the DRIVE-CLiQ com‐
0.5 Hz
ponents.
Flashing light
DRIVE-CLiQ component firmware update com‐
2 Hz
pleted. Waiting for POWER ON of the correspond‐
ing component.
Flashing light
Recognition of the component via LED is activa‐
2 Hz
ted (see SINAMICS S120/S150 List Manual.)
Note:
Both options depend on the LED status when
component recognition is activated.
Off
Cyclic communication has not (yet) taken place.
Note:
PROFIdrive is ready for communication when the
Control Unit is ready (see LED: RDY).
Continuous light
Cyclic communication is taking place.
Flashing light
Full cyclic communication is not yet taking place.
0.5 Hz
Possible causes:
● The controller is not transferring any setpoints.
● During isochronous operation, no GC (Global
Control) or a faulty GC is transferred by the
controller.
Flashing light
The PROFIBUS master is sending a faulty param‐
0.5 Hz
eter assignment or the configuration file is corrup‐
ted.
Flashing light
Cyclic bus communication has been interrupted
2 Hz
or could not be established.
Off
-
Off
-
Continuous light
The voltage of the electronics power supply for
the measuring system is 24 V.
Service cases - hardware
4.9 Control Unit CU320-2 PN and CU310-2 PN
1)
Remedy
Check the power sup‐
ply
-
-
-
Check parameter as‐
signment/configuration
Install the missing li‐
censes.
-
Switch on the compo‐
nent.
-
-
-
-
Modify the configura‐
tion between master/
controller and Control
Unit.
Rectify the bus com‐
munication fault.
-
-