Maintenance
7.3 Repair
Sealing measures when reassembling
Due to the stricter requirements of degree of protection IP55, joint sealant must be used for
motors from the 1PH7 series.
Clean bare joints between parts before reassembling (e.g. between enclosures, end shields
and the active parts of bearings).
Coat the bare joints between parts with a non-hardening sealant, e.g. MARSTON HYLOMAR
SQM32M.
Note
MARSTON HYLOMAR SQM32M sealant can be ordered from W. Kopp, Schlesierstrasse 9,
97268 Kirchheim, Germany, or directly from Marston Bentley Domsel GmbH,
Bergheimer Str. 15, 53909 Zülpich, Germany.
Notice
Please note that these joints between parts (e.g. the sealing gap between the enclosure and
end shield) must also be resealed with a suitable, silicone-free sealant during assembly.
7-14
Siemens AG A5E00177602A
Operating Instructions V 2.0 1PH728