[ID: 339.01]

3.9 Connecting the sensor module

Signal connection
The signal connection between the motor and the converter is via the DRIVE-CLiQ cable
MOTION-CONNECT. Always use prefabricated cables from SIEMENS. Thes cables reduce
the mounting/installation time and costs and increase operational reliability.
Push the connector on the DRIVE-CLiQ cable into the socket until the catch spring latches
into place. Pay attention to the coding of the connector.
Cable outlet directions
The sensor module is mounted on the motor terminal box. The sensor module can be
rotated through approximately 235°. You can change the cable outlet directions by rotating
the sensor module, as shown in the diagram below.
Notice
Do not turn the sensor module with a pipe wrench or hammer or any similar tool. This could
damage the sensor module.
Turn the sensor module by hand.
Typical twisting moment:
Figure 3-8
Siemens AG A5E00177602A
Operating Instructions V 2.0 1PH728
4 to 8 Nm
Sensor module ① mounted on terminal box
Installation / Assembly
3.9 Connecting the sensor module
3-13