Operation

5.2 Stoppages

[ID: 348]
5.2 Stoppages
Measures when motors are at standstill and ready for operation
• For longer periods, where the motor is not being used, either energize the motor at
regular intervals (roughly once a month) or at least spin the rotor.
• Please refer to the section "Energizing", before restarting the motor.
Notice
If the motor is out of service for extended periods of time, implement suitable anti-
corrosion, preservation, and drying measures.
Note
When restarting the motor after a long shutdown period, carry out the measures
recommended in the section entitled "Commissioning".
[ID: 349]
5.3 De-energizing
Measures
Always refer to the respective manual of the frequency converter when de-energizing.
If the motor is stopped for longer periods of time, switch off the fan unit and switch on the
space heater (if fitted).
[ID: 350]
5-2
Siemens AG A5E00177602A
Operating Instructions V 2.0 1PH728