Mounting On A Pedestal - Siemens SIMATIC NET SCALANCE M826 Operating Instructions Manual

Industrial remote communication remote networks
Hide thumbs Also See for SIMATIC NET SCALANCE M826:
Table of Contents

Advertisement

3.6

Mounting on a pedestal

Installation
1. Place the third housing guide of the device on the top edge of the pedestal
2. Press the device down against the pedestal until the spring catch locks in place
3. Connect the power supply, refer to the section "Power supply (Page 45)".
4. Fit the connectors for the digital input and digital output, refer to the section "Digital
input/output (Page 42)".
5. Connect the device to the DSL connection, refer to the section "DSL connection
(Page 47)".
6. Connect the device to the local network, refer to the section "Ethernet port (Page 52)".
7. Connect the terminal with as short a cable as possible ≤ 150 mm and a large cross-
sectional area ≥ 1.5 mm² to the functional ground of the system, see section "Grounding
(Page 41)" and section "Terminals (Page 23)".
Dismantling
1. Disconnect all connected cables.
2. Using a screwdriver, pull down the catch on the rear of the device.
3. Remove the device from the pedestal.
SCALANCE M826
Operating Instructions, 08/2018, C79000-G8976-C362-05
Installation
3.6 Mounting on a pedestal
.
.
35