Siemens SIMATIC NET SCALANCE M826 Operating Instructions Manual page 40

Industrial remote communication remote networks
Hide thumbs Also See for SIMATIC NET SCALANCE M826:
Table of Contents

Advertisement

Connecting up
4.1 Safety when connecting up
Safety notices on use in hazardous areas
General safety notices relating to protection against explosion
EXPLOSION HAZARD
Do not connect or disconnect cables to or from the device when a flammable or
combustible atmosphere is present.
Safety notices for use according to ATEX and IECEx
If you use the device under ATEX or IECEx conditions you must also keep to the following
safety notices in addition to the general safety notices for protection against explosion:
Take measures to prevent transient voltage surges of more than 40% of the rated voltage.
This is the case if you only operate devices with SELV (safety extra-low voltage).
Safety notices when using the device according to Hazardous Locations (HazLoc)
If you use the device under HazLoc conditions you must also keep to the following safety
notices in addition to the general safety notices for protection against explosion:
This equipment is suitable for use in Class I, Division 2, Groups A, B, C and D or non-
hazardous locations only.
This equipment is suitable for use in Class I, Zone 2, Group IIC or non-hazardous locations
only.
EXPLOSION HAZARD
You may only connect or disconnect cables carrying electricity when the power supply is
switched off or when the device is in an area without inflammable gas concentrations.
40
WARNING
WARNING
WARNING
Operating Instructions, 08/2018, C79000-G8976-C362-05
SCALANCE M826

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents