3.6

Connecting to Network

Network settings are required on the unit to be connected to a network.
Connect the LAN cables after completing the network settings on the unit.
Important
 A full understanding of LAN is required to connect the unit to a network.
 Establish a dedicated LAN for connecting the unit to a network.
 Connection to an in-house network or an existing LAN requires caution, since specific
restrictions or rules may have been applied to the IP address management. Consult your
network administrator. In case that such a network is used, however, OMRON cannot
guarantee the performance of the unit and the PC software.
 The measurement operation mode (MODE) still must be set to "NORM" if the IP address and
subnet masks settings use its default values. Also set the network function availability (NET) to
"ON". Network connection is not possible when "SLEEP" or "HISPD" measurement mode
(MODE) is entered. (ZN-CTX21 only)

3.6.1 Preparation

Define the IP addresses and subnet masks to use before establishing network connection.
Setting Example
IP Address of the unit
PC IP Address
Subnet Mask
IP Address: 192.168.0.20
Subnet Mask: 255.255.255.0
(Unit 1): 192.168.0.20 (Factory default)
(Unit 2): 192.168.0.21
192.168.0.100
255.255.255.0 (Factory default)
IP Address: 192.168.0.100
Subnet Mask: 255.255.255.0
LAN Cable
IP Address: 192.168.0.21
Subnet Mask: 255.255.255.0
3-14
3. Check and Preparation
W4S1-05C
(Operation
check completed)