Appendix; Ratings And Performance; Zn-Ctx21 - Omron EQUO Series User Manual

Portable power monitor; power sensor station;
Hide thumbs Also See for EQUO Series:
Table of Contents

Advertisement

6.

Appendix

6.1

Ratings and Performance

6.1.1 ZN-CTX21

Item
Connectable Sensor
Display
Recording Interval
Operation Function
Measurement
Operation Mode
Recording Mode
External Output
Memory Capacity
(Internal)
Memory Capacity
(External)
Power Supply
Current Consumption
9
Battery Life*
Operating Temperature
Operating Humidity
Storage
Humidity/Temperature
Insulation Resistance
Withstand Voltage
Vibration Resistance
Shock Resistance
Material
Degree of Protection
Mounting
Dimensions (WDH)
Weight (in Package)
Accessories1
Accessories1
*1: In high-speed logging mode, data is recorded in 83 ms at 60 Hz and in 100 ms at 50 Hz.
*2: Momentary power and integrated power values are converted from the measured current.
Correctly specify the number of used channels, applicable measurement target circuit, CT type,
frequency, voltage and power factor.
*3: The display turns OFF after 10 seconds of no user operation and recovers by a key operation
when SLEEP mode is specified. LAN cannot be used when sleep mode is specified.
ZN-CTX21
ZN-CTS□1-□A, ZN-CTM□1-□A
7-seg. 5-digit 2-step LCD display, auxiliary information indicator displays
1 s, 2 s, 5 s, 10 s, 20 s, 30 s, 1 min.
Momentary power, Integrated power consumption
Normal mode, Sleep mode*
4
Continue mode*
, Ring mode*
Alarm output (Photocoupler output) *
Internal memory: approx. 6500 data items (The number of CHs is 1)
SD memory card (SDHC support, measured value saving/set value saving
and reading),
Recommended SD memory card: HMC-SD291 (2GB) / HMC-SD491
(4GB) (manufactured by OMRON)
DC input: 24 VDC±10%
AC adapter: 100 to 240 VAC/50 to 60 Hz
Batteries: Two AAA batteries*
Max. 80 mA (AC adapter used)
10
Approx. 1 week*
Battery Supply: -10°C to 60°C (no condensation or icing)
AC Adapter: 0°C to 40°C (no condensation or icing)
20 to 85%RH (no condensation or icing)
-15°C to +60°C, 20 to 85%RH (no condensation or icing)
20 MΩ (with DC500VDC)
1000 VAC, 50/60 Hz, 1 min.: Between the case and current input circuit
With mounting screws: 10 to 150 Hz, 0.7 mm double amplitude,
2
acceleration: 50 m/s
for each in X, Y and Z directions for 80 min.
With mounting magnets: 10 to 55 Hz, 0.3 mm double amplitude,
2
acceleration: 20 m/s
for each in X, Y and Z directions for 50 min.
150 m/s2 in 6 directions (+/-X, +/-Y, and +/-Z directions), 3 times each*
ABS
IP30
Magnet mounting, screw mounting, hook, free standing
117.2 × 24.6 × 56.8 mm (Excluding protrusions)
Approx. 500 g
Instruction Sheet, Startup Guide, Mounting Magnets*
13
Connector*
14
AC Adapter*
6-1
ZN-CTX21-A
*1
*2
3
, High-speed logging mode
5
6
*7
8
DC cable, Ferrite core
Appendix
11
12
, Alarm Output

Advertisement

Table of Contents
loading

This manual is also suitable for:

Equo zn-kmx21Equo zn-ctx21

Table of Contents