Installation - True TBR Series Installation Manual

Hide thumbs Also See for TBR Series:
Table of Contents

Advertisement

TRUE
TBR | TDR SERIES

INSTALLATION

PRIOR TO INSTALLATION
OWNERSHIP
To ensure that your unit works properly from the first day, it must
be installed properly. We highly recommend a trained refrigeration
mechanic and electrician install your TRUE equipment. The cost of
a professional installation is money well spent.
Before you start to install your TRUE unit, carefully inspect it for
freight damage. If damage is discovered, immediately file a claim
with the delivery freight carrier.
TRUE is not responsible for damage incurred during shipment.
CABINET SPECIFICATION
• This appliance is listed for the storage and/or display of open
food product.
CABINET LOCATION
• Appliance tested for IEC to ISO Climate Class 5
(104°F/40° C temperature, 40% relative humidity).
• For proper operation, ambient temperatures shall not be less
than 60°F/15.5°C and no greater than 104°F/40°C
• Appliance is not suitable for outdoor use.
• Appliance is not suitable for an area where a water jet or
hose may be used.
• Ensure the location will provide adequate clearances and
sufficient airflow for the cabinet.
• Ensure the power supply for the cabinet matches the cabinet
specification sheet or cabinet data plate and is within the
rated voltage (+/-5%). Also, that the amp rating of the circuit
is correct and that it is properly grounded.
• The cabinet should always be plugged into its own individual
dedicated electrical circuit. The use of adapter plugs and
extension cords is prohibited.
NOTICE TO CUSTOMER
Loss or spoilage of products in your refrigerator/freezer is not
covered by warranty. In addition to following recommended
installation procedures, you must run the refrigerator/freezer for
24 hours prior to usage to verify its proper operation.
CLEARANCES
TBR/TDR
WARNING: WARRANTY IS VOID IF
VENTILATION IS INSUFFICIENT.
TOP
SIDES
BACK
1" (25.4 mm)
1" (25.4 mm)
1" (25.4 mm)
WIRE GAUGE CHART
115
Volts
Distance In Feet To Center of Load
AMPS
20
30
40
50
2
14
14
14
14
3
14
14
14
14
4
14
14
14
14
5
14
14
14
14
6
14
14
14
14
7
14
14
14
14
8
14
14
14
14
9
14
14
14
12
10
14
14
14
12
12
14
14
12
12
14
14
14
12
10
16
14
12
12
10
18
14
12
10
10
20
14
12
10
10
25
12
10
10
8
30
12
10
8
8
35
10
10
8
6
40
10
8
8
6
45
10
8
6
6
50
10
8
6
6
230
Volts
Distance In Feet To Center of Load
AMPS
20
30
40
50
5
14
14
14
14
6
14
14
14
14
7
14
14
14
14
8
14
14
14
14
9
14
14
14
14
10
14
14
14
14
12
14
14
14
14
14
14
14
14
14
16
14
14
14
14
18
14
14
14
12
20
14
14
14
12
25
14
14
12
12
30
14
12
12
10
35
14
12
10
10
40
14
12
10
10
50
12
10
10
8
60
12
10
8
6
70
10
10
8
6
80
10
8
8
6
90
10
8
6
6
100
10
8
6
6
truemfg.com
60
70
80
90
100
120
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
12
14
14
14
12
12
12
14
14
12
12
12
10
14
12
12
12
10
10
12
12
12
10
10
10
12
12
10
10
10
8
12
10
10
10
10
8
10
10
10
8
8
8
10
10
8
8
8
6
10
8
8
8
8
6
8
8
8
8
8
8
8
8
8
6
6
6
8
6
6
6
6
5
6
6
6
6
5
4
6
6
5
5
4
4
6
5
5
4
4
3
6
5
4
4
3
3
5
4
4
3
3
2
60
70
80
90
100
120
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
12
14
14
14
14
12
12
14
14
14
12
12
12
14
14
12
12
12
10
14
12
12
12
10
10
12
12
12
10
10
10
12
12
10
10
10
8
10
10
10
10
10
8
10
10
10
10
8
8
10
10
8
8
8
6
10
8
8
8
8
6
8
8
8
6
6
6
6
6
6
6
6
5
6
6
6
6
5
4
6
6
5
5
4
4
6
5
5
4
4
3
5
5
4
4
3
3
5
4
4
3
3
2
140
160
14
14
14
12
12
12
10
10
10
10
10
8
8
8
8
8
8
8
8
6
6
6
6
6
8
5
5
5
4
4
4
3
3
2
2
2
2
1
1
1
140
160
14
14
14
12
12
12
12
12
12
10
10
10
10
10
10
8
8
8
8
8
8
8
6
6
6
6
6
5
5
5
4
4
4
3
2
2
2
2
1
1
1
1
3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents