Replacing the Power backplane

4.4
Replacing the Power backplane
Ê Open the server as described in the
Ê Remove the system fan 2&4 and the system fan 1&3 as described in the
section "System fans" on page
Ê Push the green latch of the hot-plug power supply unit upward and pull the
power supply unit simultaneously out of the PS cage using the handle (see
the Operating Manual).
Ê If a second hot-plug power supply unit has been installed, remove this one
in the same way (an installed dummy cover can rest in place).
I
The Power backplane in the floorstand model is positioned directly under
the top cover and it makes sense to lay the server on a table with the
uncovered side facing upward.
Ê Disconnect all power cables from the Power backplane.
Figure 10: Removing the Power backplane
Ê Remove the screw (see circle).
Ê Push the defective Power backplane downward until it gets out of the PS
cage guides. Take out the Power backplane.
32
section "Preparation" on page
25.
Service Supplement
23.
TX200 S6