Replacing The Power Backplane - Fujitsu PRIMERGY TX600 S3 Service Supplement Manual

Table of Contents

Advertisement

Replacing the power backplane

Replacement routines
4.12
Replacing the power backplane
The power backplane is located underneath the system board close to the SCSI
backplane.
Requirements
– The server has been switched off
– The power cables have been uplugged
– Rack model only: The server has been pulled out
– The housing cover has been removed
– The system board has been removed (see
page
41)
– The power supply units have been pulled out (see Operating Manual)
Ê Disconnect the cables that are fixed to the power backplane from the system
board, the SCSI backplane and the accessible drives (see
page
50).
B
A
TP01464
Figure 27: Removing the power backplane
Ê Undo the seven screws (A) of the power backplane and remove it (B).
To install the power backplane perform the above procedure in reverse.