Replacing the power backplane
Replacement routines
4.12
Replacing the power backplane
The power backplane is located underneath the system board close to the SCSI
backplane.
Requirements
– The server has been switched off
– The power cables have been uplugged
– Rack model only: The server has been pulled out
– The housing cover has been removed
– The system board has been removed (see
page
41)
– The power supply units have been pulled out (see Operating Manual)
Ê Disconnect the cables that are fixed to the power backplane from the system
board, the SCSI backplane and the accessible drives (see
page
50).
B
A
TP01464
Figure 27: Removing the power backplane
Ê Undo the seven screws (A) of the power backplane and remove it (B).
To install the power backplane perform the above procedure in reverse.
44
Service Supplement TX600 S3