Temperature
Fresh air
Maximum temperature gradient (operating
and storage)
Table 2: Relative humidity
Relative humidity
Storage
Operating
Table 3: Maximum vibration
Maximum vibration
Operating
Storage
Table 4: Maximum shock
Maximum shock
Operating
Storage
Table 5: Maximum altitude
Maximum altitude
Operating
Storage
Table 6: Operating temperature de-rating
Operating temperature de-rating
Up to 35°C (95°F)
35°C to 40°C (95°F to 104°F)
40°C to 45°C (104°F to 113°F)
December 2018
Specifications
For information about fresh air, see Expanded Operating
Temperature section.
20°C/h (68°F/h)
Specifications
5% to 95% RH with 33°C (91°F) maximum dew point.
Atmosphere must be non-condensing at all times.
10% to 80% relative humidity with 29°C (84.2°F)
maximum dew point.
Specifications
0.26 G
rms
1.88 G
rms
tested).
Specifications
Six consecutively executed shock pulses in the positive
and negative x, y, and z axes of 6 G for up to 11 ms.
Six consecutively executed shock pulses in the positive
and negative x, y, and z axes (one pulse on each side of
the system) of 71 G for up to 2 ms.
Specifications
3048 m ( 10,000 ft)
12,000 m (39,370 ft)
Specifications
Maximum temperature is reduced by 1°C/300 m (1°F/547
ft) above 950 m (3,117 ft).
Maximum temperature is reduced by 1°C/175 m (1°F/319
ft) above 950 m (3,117 ft).
Maximum temperature is reduced by 1°C/125 m (1°F/228
ft) above 950 m (3,117 ft).
Installing the Avaya Converged Platform 120 Series
Comments on this document? infodev@avaya.com
Environmental requirements
at 5 Hz to 350 Hz (all operation orientations).
at 10 Hz to 500 Hz for 15 min (all six sides
15

Advertisement

Table of Contents
loading

This manual is also suitable for:

Acp 120Acp 110Acp 130

Table of Contents