F.5.3: Nac Type Codes - Honeywell Notifier NFS2-640/E Programming Manual

Fire alarm control panel
Hide thumbs Also See for Notifier NFS2-640/E:
Table of Contents

Advertisement

Type Codes
GEN SUPERVIS
N
GEN TROUBLE
N
GENERAL PEND
N
TROUBLE PEND
N
MNS GENERAL
N
1
MNS CONTROL
N
1
MNS STROBE
N
1
MNS SPEAKER
N
1
MNS RELAY
N
*
The FCM-1-REL checks for shorts with all releasing type codes.
1
The type code is not compatible with FirstCommand applications.
F.5.3 NAC Type Codes
A comprehensive list of Type Codes for panel NACs. For instructions on programming Type
Codes, refer to "Modify or Delete a Point (2=point)" on page 19.
Type Code
CONTROL
BELL CIRCUIT
STROBE CKT
HORN CIRCUIT
AUDIBLE CKT
SPEAKER
REL END BELL
blank label
REL CKT ULC
RELEASE CKT
REL AUDIBLE
REL CODE
BELL
INSTANT RELE
ALARMS PEND
CONTROL NAC
GEN ALARM
GEN SUPERVIS
GEN TROUBLE
116
Table F.3 Control Module Type Codes (2 of 2)
NAC
Control Module, an XPR-8 relay, or an XP5-C (in relay mode) activated under any
Supervisory condition (includes sprinkler type). It is programmed as "switch inhibit".
NAC
Control Module, an XPR-8 relay, or an XP5-C (in relay mode) activated under any
System Trouble condition. It is programmed as "switch inhibit".
NAC
Control Module, an XPC-8 circuit, or an XP5-C (in NAC mode) that will activate upon
receipt of an alarm and/or trouble condition, and remain in the ON state until all events
have been ACKNOWLEDGED.
NAC
Control Module, an XPC-8 circuit, or an XP5-C (in NAC mode) that will activate upon
receipt of a trouble condition, and remain in the ON state until all troubles have been
ACKNOWLEDGED. It is programmed as "switch inhibit".
NAC
Mass notification supervised output.
NAC
Mass notification supervised NAC.
NAC
Mass notification supervised NAC.
NAC
Mass notification supervised NAC for speaker circuits.
NAC
Mass notification relay output.
Table F.4 NAC Type Codes
Silenceable
Device Function
(Y/N)
Y
Supervised NAC
Y
Supervised NAC for notification appliance
Y
Supervised NAC for notification appliance
Y
Supervised NAC for notification appliance
Y
Supervised NAC for notification appliance
N
Supervised NAC for speaker circuits
N
Supervised NAC
Y
Supervised NAC for undefined device
N
Releasing Circuit, power-limited, supervised for opens, shorts and
ground faults (always non-silenceable)
N
Releasing circuit, nonpowerlimited, supervised for opens and
ground faults
Y
NAC, activated upon release
Y
Supervised NAC (NFS2-640 NAC only)
N
NAC, short = normal; supervised for open circuits and ground
faults. Always non-silenceable and switch-inhibited.
N
Output that will activate upon receipt of an alarm condition, and
remain in the alarm state until all alarms have been acknowledged.
It is programmed as "switch inhibit".
Y
Supervised NAC
N
Control Module, an XPC-8 circuit, or an XP5-C (in NAC mode)
configured as a Municipal Box Transmitter for NFPA 72-2002
Auxiliary Fire Alarm Systems applications (MBT-1 required). This
Type ID can also be used for general alarm activation. It is
programmed as "switch inhibit".
N
Control Module, an XPR-8 relay, or an XP5-C (in relay mode)
activated under any Supervisory condition (includes sprinkler type).
It is programmed as "switch inhibit".
N
Control Module, an XPR-8 relay, or an XP5-C (in relay mode)
activated under any System Trouble condition. It is programmed as
"switch inhibit".
NFS2-640/E Programming Manual — P/N 52742:L2 7/17/14