Viessmann Vitodens 200-W Series Installation And Service Instructions Manual page 82

Wall mounted
Table of Contents

Advertisement

Troubleshooting
Fault codes
(cont.)
Displayed
Const.
fault code
E2
X
E3
X
E4
X
E5
X
E6
X
E7
X
E8
X
82
Weath.-
System characteris-
comp.
tics
X
Burner in a fault state Heating water flow
X
Burner in a fault state Heat transfer too
X
Burner blocked
X
Burner blocked
X
Burner blocked
X
Burner in a fault state Ionisation current
X
Burner in a fault state The ionisation cur-
Cause
Measures
Ensure adequate circula-
rate too low during
tion volume.
calibration. Flow
Check flow switch.
switch caused
Remove scaling, block-
shutdown.
age.
Press reset button R.
Ensure adequate heat
low during calibra-
transfer.
tion.
Press reset button R.
Temperature limiter
caused shutdown.
Fault, supply volt-
Replace control unit.
age 24 V
Fault, flame ampli-
Replace control unit.
fier
System pressure
Top up with water.
too low
Check ionisation elec-
too low during cali-
trode:
bration
Distance to burner
gauze assembly (see
page 32)
Contamination of elec-
trode
Connecting lead and
plug-in connections
Check flue system; reme-
dy flue gas recirculation if
required.
Press reset button R.
Check gas supply (gas
rent lies outside
pressure and gas flow
the permissible
switch), gas train and
range
connecting lead.
Check allocation of gas
type (see page 26).
Check ionisation elec-
trode:
Distance to burner
gauze assembly (see
page 32)
Contamination of elec-
trode
Press reset button R.