Viessmann Vitodens 200-W Series Installation And Service Instructions Manual page 79

Wall mounted
Table of Contents

Advertisement

Fault codes
(cont.)
Displayed
Const.
fault code
9C
X
9E
X
9F
X
A3
A4
A7
b0
X
b1
X
b5
X
b7
X
b8
X
bA
bb
Weath.-
System characteris-
comp.
tics
X
No solar DHW heat-
ing
X
Control mode
X
Control mode
X
Burner blocked.
X
Control mode
X
Control mode as per
delivered condition
X
Burner blocked
X
Control mode as per
delivered condition
X
Control mode as per
delivered condition
X
Burner blocked
X
Burner blocked
X
Mixer regulates to
20 °C flow tempera-
ture.
X
Mixer regulates to
20 °C flow tempera-
ture.
Cause
Measures
Lead break, cylin-
Check temperature sen-
der temperature
sor
%
sensor
module or sensor on the
Vitosolic.
No flow rate in col-
Check solar circuit pump
lector circuit or flow
and solar circuit. Acknowl-
rate too low, or
edge fault message.
temperature limiter
has responded
Solar control mod-
Replace solar control
ule or Vitosolic
module or Vitosolic
faulty
Flue gas tempera-
Install flue gas tempera-
ture sensor not
ture sensor correctly (see
positioned correct-
page 88).
ly.
Max. system pres-
Check system pressure
sure exceeded
(max. system pressure
3 bar (0.3 MPa)).
Check the function and
sizing of the diaphragm
expansion vessel.
Vent the heating system.
Programming unit
Replace programming
faulty
unit
Short circuit, flue
Check flue gas tempera-
gas temperature
ture sensor
sensor
Communication er-
Check connections and
ror, programming
replace programming unit
unit
if required
Internal fault
Replace the control unit
Boiler coding card
Plug in boiler coding card
faulty
or replace if faulty
Lead break, flue
Check flue gas tempera-
gas temperature
ture sensor
sensor
Communication er-
Check extension kit con-
ror, extension kit
nections and code.
for heating circuit 2
(with mixer)
Communication er-
Check extension kit con-
ror, extension kit
nections and code.
for heating circuit 3
(with mixer)
Troubleshooting
on solar control
79

Advertisement