AudioCodes Gateway & Session Border Controller Series Hardware Installation Manual
AudioCodes Gateway & Session Border Controller Series Hardware Installation Manual

AudioCodes Gateway & Session Border Controller Series Hardware Installation Manual

Advertisement

Quick Links

Hardware Installation Manual
AudioCodes Gateway & Session Border Controller Series
Mediant 500 Gateway
and E-SBC
Version 7.2

Advertisement

Table of Contents
loading

Summary of Contents for AudioCodes Gateway & Session Border Controller Series

  • Page 1 Hardware Installation Manual AudioCodes Gateway & Session Border Controller Series Mediant 500 Gateway and E-SBC Version 7.2...
  • Page 2 Please contact your local recycling authority for disposal of this product. Customer Support Customer technical support and services are provided by AudioCodes or by an authorized AudioCodes Service Partner. For more information on how to buy technical support for AudioCodes products contact...
  • Page 3 Notice Mediant 500 Gateway & E-SBC | Hardware Installation Manual Caution Electrical Shock: Do not open or disassemble this device. The device carries high voltage and contact with internal components may expose you to electrical shock and bodily harm. The device must be installed and serviced only by qualified service personnel. For deployment in Finland, Sweden and Norway, the device must be installed only in restricted access locations that are compliant with ETS 300253 guidelines where equipotential bonding has been implemented.
  • Page 4: Table Of Contents

    Content Mediant 500 Gateway & E-SBC | Hardware Installation Manual Table of Contents 1 Introduction 2 Unpacking the Device 3 Physical Description Physical Dimensions Front Panel Description Ports and Buttons LED Descriptions Operational Status LED LAN Interface LED E1/T1 LEDs Power LED Rear Panel Description 4 Mounting the Device...
  • Page 5: Introduction

    Serial console port (RJ-45) for device management ● Serial Hardware configurations may change without notice. Currently available hardware configurations are listed in AudioCodes Price Book. For further enquiries, please contact your AudioCodes sales representative. ● For information on configuring the device, refer to the device's User’s Manual.
  • Page 6: Unpacking The Device

    Two mounting brackets for 19-inch rack mounting ● Serial cable adapter ● One AC power cable ● (Optional) Wall-mounting kit (separate-orderable item) Check, retain and process any documents. If there are any damaged or missing items, notify your AudioCodes sales representative. - 2 -...
  • Page 7: Physical Description

    CHAPTER 3    Physical Description Mediant 500 Gateway & E-SBC | Hardware Installation Manual Physical Description This section provides a physical description of the device. Physical Dimensions The device's physical dimensions and weight are listed in the following table: Table 3-1: Physical Dimensions Physical Specification Value Dimensions (H x W x D)
  • Page 8: Led Descriptions

    CHAPTER 3    Physical Description Mediant 500 Gateway & E-SBC | Hardware Installation Manual Item # Label Description CONSOLE RJ-45 port for RS-232 serial communication Up to four Gigabit Ethernet (10/100/1000Base-T) ports for connecting to LAN network (IP phones, computers, or switches). These ports support half- and full-duplex modes, auto- negotiation, and straight or crossover cable detection.
  • Page 9: E1/T1 Leds

    CHAPTER 3    Physical Description Mediant 500 Gateway & E-SBC | Hardware Installation Manual E1/T1 LEDs The E1/T1 trunk port provides a LED for indicating operating status, as described in the following table: Table 3-5: E1/T1 LED Description Color State Description Green Trunk is synchronized (normal operation).
  • Page 10: Mounting The Device

    CHAPTER 4    Mounting the Device Mediant 500 Gateway & E-SBC | Hardware Installation Manual Mounting the Device The device can be mounted in one of the following ways: ■ Placed on a desktop – see Desktop Mounting below ■ Installed in a standard 19-inch rack – see Wall Mounting on the next page Do not place any equipment directly on top of the device or adjacent to its sides (at least...
  • Page 11: Wall Mounting

    CHAPTER 4    Mounting the Device Mediant 500 Gateway & E-SBC | Hardware Installation Manual Wall Mounting You can mount the device on a wall, using a special wall-mounting bracket. The bracket enables you to hang the device in a horizontal (rear panel facing up) or vertical (rear panel facing right) position.
  • Page 12 CHAPTER 4    Mounting the Device Mediant 500 Gateway & E-SBC | Hardware Installation Manual ● Vertical position: The horizontal distance between the keyholes is 135 mm (5.31 in.) and the vertical distance is 200 mm (7.87 in.): Figure 4-4: Keyhole Dimensions for Vertical Wall-Mounting Drill holes in the wall where you marked the keyholes.
  • Page 13 CHAPTER 4    Mounting the Device Mediant 500 Gateway & E-SBC | Hardware Installation Manual Figure 4-7: Removing Side-Panel Screws Place the bracket on a flat surface, and then with two hands, hold the device above the bracket so that its bottom panel faces the bracket and its rear panel is on the same side as the bracket's grounding-screw hole.
  • Page 14 CHAPTER 4    Mounting the Device Mediant 500 Gateway & E-SBC | Hardware Installation Manual Figure 4-10: Attaching Bracket to Device using Grounding Screw If you are grounding the device, attach the grounding lug at the same time: Figure 4-11: Attaching Bracket to Device using Ground Screw with Grounding Lug Using a Phillips-head screwdriver, attach the bracket to the left- and right-side panels, using two screws for each side (which you removed previously in Step 6): Figure 4-12: Attaching Bracket to Device using Side-Panel Screws...
  • Page 15: 19-Inch Rack Mounting

    CHAPTER 4    Mounting the Device Mediant 500 Gateway & E-SBC | Hardware Installation Manual Figure 4-14: Hanging Device on Screw Heads for Vertical Orientation 19-Inch Rack Mounting The device can be installed in a standard 19-inch rack by implementing one of the following mounting methods: ■...
  • Page 16: Using Mounting Brackets

    CHAPTER 4    Mounting the Device Mediant 500 Gateway & E-SBC | Hardware Installation Manual ➢ To mount the device on a pre-installed shelf in the rack: Before installing it in the rack, ensure that you have a pre-installed rack shelf on which the device can be placed.
  • Page 17 CHAPTER 4    Mounting the Device Mediant 500 Gateway & E-SBC | Hardware Installation Manual ● 1 = Left mounting bracket ● 2 = Attached screws ● 3 = Right mounting bracket Place the device on a pre-installed shelf in the rack. Attach the ends of the mounting brackets (that you installed in Step 1) to the vertical track of the rack's frame, using standard 19-inch rack bolts (not supplied).
  • Page 18: Cabling The Device

    CHAPTER 5    Cabling the Device Mediant 500 Gateway & E-SBC | Hardware Installation Manual Cabling the Device This section describes the cabling of the device. Grounding the Device The device must be connected to earth (grounded) using an equipment-earthing conductor. Protective Earthing: The equipment is classified as Class I EN60950 and UL60950 and must be earthed at all times.
  • Page 19: Connecting To An Isdn Pri (E1/T1) Trunk

    CHAPTER 5    Cabling the Device Mediant 500 Gateway & E-SBC | Hardware Installation Manual Signal Name Ethernet signal pair (1000Base-T) Ethernet signal pair (1000Base-T) Shield Chassis ground ➢ To connect the device to the LAN: Connect one end of a straight-through RJ-45 Cat 5e or Cat 6 cable to the RJ-45 port labeled S1 / LAN GE.
  • Page 20: Connecting The Serial Interface To A Pc

    CHAPTER 5    Cabling the Device Mediant 500 Gateway & E-SBC | Hardware Installation Manual Figure 5-4: Cabling E1/T1 Port Connecting the Serial Interface to a PC The device provides an RS-232 serial interface port on its front panel. The serial cable adapter used for connecting the RS-232 interface is shown below: Figure 5-5: RS-232 Cable Adapter...
  • Page 21: Connecting A Usb Storage Device

    CHAPTER 5    Cabling the Device Mediant 500 Gateway & E-SBC | Hardware Installation Manual Figure 5-6: Cabling Serial Port Connect the other end of the cable providing the 9-pin DB connector to the COM RS-232 communication port on your computer. Connecting a USB Storage Device The device supports USB storage capabilities, using an external USB hard drive or flash disk (disk on key) connected to the device's USB port.
  • Page 22: Connecting To The Power Supply

    CHAPTER 5    Cabling the Device Mediant 500 Gateway & E-SBC | Hardware Installation Manual Connecting to the Power Supply The device receives power from a standard alternating current (AC) electrical outlet. The connection is made using the supplied AC power cord. Table 5-3: Power Specifications Physical Specification Value...
  • Page 23 CHAPTER 5    Cabling the Device Mediant 500 Gateway & E-SBC | Hardware Installation Manual This page is intentionally left blank. - 19 -...
  • Page 24 Website: https://www.audiocodes.com/ ©2019 AudioCodes Ltd. All rights reserved. AudioCodes, AC, HD VoIP, HD VoIP Sounds Better, IPmedia, Mediant, MediaPack, What’s Inside Matters, OSN, SmartTAP, User Management Pack, VMAS, VoIPerfect, VoIPerfectHD, Your Gateway To VoIP, 3GX, VocaNom, AudioCodes One Voice, AudioCodes Meeting Insights, AudioCodes Room Experience and CloudBond are trade- marks or registered trademarks of AudioCodes Limited.

This manual is also suitable for:

Mediant 500E-sbc

Table of Contents