AudioCodes Mediant 500 Quick Manual
AudioCodes Mediant 500 Quick Manual

AudioCodes Mediant 500 Quick Manual

Connecting pbx to broadsoft sip trunk using audiocodes mediant pri gateway
Hide thumbs Also See for Mediant 500:

Advertisement

Quick Guide
AudioCodes Mediant™ Gateway
Connecting PBX to BroadSoft SIP Trunk
using AudioCodes Mediant PRI Gateway
Version 7.2

Advertisement

Table of Contents
loading

Summary of Contents for AudioCodes Mediant 500

  • Page 1 Quick Guide AudioCodes Mediant™ Gateway Connecting PBX to BroadSoft SIP Trunk using AudioCodes Mediant PRI Gateway Version 7.2...
  • Page 2 Introduction See Chapter 1 Obtain Software Files See Chapter 2 Cable Device for Initial Access See Chapter 3 Upload Software to Device See Chapter 4 Configure & Reset Device See Chapter 5 Cable Device to DMZ See Chapter 6...
  • Page 3: Component Information

    Quick Guide 1. Introduction Introduction This document describes how to set up AudioCodes' PRI Gateway (hereafter, referred to as Gateway) for interworking between BroadSoft's SIP Trunk and PBX environment. For detailed information on each AudioCodes Gateway, refer to the corresponding User's Manual and Hardware Installation Manual.
  • Page 4 BroadSoft SIP Trunk This page is intentionally left blank. Quick Guide Document #: LTRT-14020...
  • Page 5 Quick Guide 2. Obtain Software Files Obtain Software Files Download certified firmware file (firmware_xxx.cmp), configuration file (configuration_xxx.ini) and Call Progress Tones file (call_progress_uk.dat), of the specific AudioCodes PRI Gateway (referred as “xxx”), from Support Centre. Version 7.2 AudioCodes Mediant Gateway...
  • Page 6 BroadSoft SIP Trunk This page is intentionally left blank. Quick Guide Document #: LTRT-14020...
  • Page 7 • Ground the device using the grounding lug. • Using the supplied AC power cable, connect the device's AC port to a standard electrical wall outlet. Figure 3-1: Mediant 500 – Front and Rear Panels Version 7.2 AudioCodes Mediant Gateway...
  • Page 8 BroadSoft SIP Trunk Figure 3-2: Mediant 800 – Front and Rear Panels Quick Guide Document #: LTRT-14020...
  • Page 9 On your PC, start your Web browser and then in the URL address field, enter the device's default IP address; the following appears: Figure 3-4: Web Login In the 'Username' and 'Password' fields, enter the default login username ("Admin") and password ("Admin"), and then click Login. Version 7.2 AudioCodes Mediant Gateway...
  • Page 10 BroadSoft SIP Trunk This page is intentionally left blank. Quick Guide Document #: LTRT-14020...
  • Page 11 Cancel. However, if you continue with the wizard and start loading the CMP file, the upgrade process must be completed with a device reset. Click Browse, and then navigate to and select the .cmp file. Version 7.2 AudioCodes Mediant Gateway...
  • Page 12 BroadSoft SIP Trunk Click Load File; the device begins to install the .cmp file and a progress bar displays the status of the loading process: Figure 4-3: CMP File Loading Progress Bar A message is displayed to inform you that the file has been loaded,. When successfully loaded, click Next to access the wizard page for loading the ini file.
  • Page 13 Figure 4-5: Load an CPT File in the Software Upgrade Wizard Keep clicking Next until the last Wizard page appears (the FINISH button is highlighted in the left pane) and the following message appears: Figure 4-6: Software Upgrade Wizard – Google Chrome Version 7.2 AudioCodes Mediant Gateway...
  • Page 14 BroadSoft SIP Trunk Click Reset to install the files by saving them on the device's flash memory with a device. Once complete, the following is displayed: Figure 4-7: Current CMP Version ID Click End Process to close the wizard, and then log in again to the Web interface. Enter your login username and password (Admin, Admin respectively), and then click Login;...
  • Page 15: Configure Device

    SIP settings such as proxy server addresses. Therefore, to prevent an attacker from obtaining sensitive SIP settings that could result in possible call theft etc., change its default login password to a hard-to-hack string. Version 7.2 AudioCodes Mediant Gateway...
  • Page 16: Configure A Network Interface For The Device

    BroadSoft SIP Trunk Configure a Network Interface for the Device You can connect the device to the DMZ network using one of the following methods:  Method A: (Preferred method) A global IP address is provided to the device (without NAT): Figure 5-2: Method A The Enterprise firewall is configured with rules, for example:...
  • Page 17 Secondary DNS Server IP Secondary DNS IP address (optional) Address Click Apply. The figure below shows an example of a configured IP network interface. Figure 5-4: Example of a Configured Network Interface in IP Interfaces Table Version 7.2 AudioCodes Mediant Gateway...
  • Page 18: Configure Nat

    BroadSoft SIP Trunk 5.2.2 Configure NAT Note: • NAT configuration is applicable only if you are behind a firewall NAT (see • Method • The NAT IP Address is the Global-IP-address used in front of the firewall facing the BroadSoft service. If the DMZ holds the global-IP-address (no NAT is performed by the firewall) and the Gateway is already assigned the Global-IP-address as its address, skip this NAT configuration.
  • Page 19: Configure General Sip Parameters

    Configure following parameters: Parameter Value Gateway Settings Use To header Source Header For Called Number Gateway Session Expires Update Session Expires Method Disconnect Supervision Broken Connection Mode Ignore Figure 5-7: Configuring SIP General Settings Parameters Click Apply. Version 7.2 AudioCodes Mediant Gateway...
  • Page 20 BroadSoft SIP Trunk 5.3.2 Configure SIP Message Structure Parameters This step shows how to add SIP P-Asserted Header.  To configure the SIP Message Structure parameters: Open the SIP Proxy & Registration Parameters page (Setup menu > Signaling & Media tab > SIP Definitions folder > Message Structure). From the 'Asserted Identity Mode' dropdown, select Add P-Asserted-Identity.
  • Page 21 Proxy Name Per SIP Trunk requirement Enable Always Use Proxy Gateway Authentication User Name Trunk Group Pilot User Password Trunk Group Pilot User Password Authentication Mode Per Gateway Gateway Registration Enable Registration Enable Registrar Name uk.ic.sipconnect.hipcom.co.uk Version 7.2 AudioCodes Mediant Gateway...
  • Page 22 BroadSoft SIP Trunk Figure 5-9: Configuring Proxy & Registration Parameters Quick Guide Document #: LTRT-14020...
  • Page 23 Configure the address of the Proxy Set per the parameters described in the table below. Parameter Value Index Proxy Address uk.ic.sipconnect.hipcom.co.uk:5060 (SIP Trunk IP address / FQDN and destination port) UDP (Network transport type for the SIP Trunk) Transport Type Click Apply. Version 7.2 AudioCodes Mediant Gateway...
  • Page 24 BroadSoft SIP Trunk 5.3.5 Configure Message Manipulation Rules This step describes how to configure SIP message manipulation rules, which can include insertion, removal, and/or modification of SIP headers. Manipulation rules are grouped into Manipulation Sets, enabling you to apply multiple rules to the same SIP message (IP entity).
  • Page 25 Full # in Diversion Manipulation Set ID Message Type any.request Condition header.diversion.url.user len== '4' header.diversion.url.user Action Subject Add Prefix Action Type '44203621' Action Value Figure 5-12: Configuring SIP Message Manipulation Rule 1 (for BroadSoft SIP Trunk) Version 7.2 AudioCodes Mediant Gateway...
  • Page 26 BroadSoft SIP Trunk Configure another manipulation rule (Manipulation Set 1) for BroadSoft SIP Trunk. This rule applies to messages sent to the BroadSoft SIP Trunk in a call transfer scenario. This will add ‘+’ prefix to the user part of SIP Refer-To Header to complete the BroadSoft SIP Trunk number conversion.
  • Page 27 Value Index Name Call Forward Manipulation Set ID Message Type invite Condition header.diversion exists header.from.url.user Action Subject Modify Action Type header.diversion.url.user Action Value Figure 5-14: Configuring SIP Message Manipulation Rule 3 (for BroadSoft SIP Trunk) Version 7.2 AudioCodes Mediant Gateway...
  • Page 28 BroadSoft SIP Trunk Figure 5-15: Example of Configured SIP Message Manipulation Rules The table displayed below includes SIP message manipulation rules which are grouped together under Manipulation Set ID 1 and which are executed for messages sent to the BroadSoft SIP Trunk. These rules are specifically required to enable proper interworking between BroadSoft SIP Trunk and PBX.
  • Page 29 Open the Coder Groups table (Setup menu > Signaling & Media tab > Coders & Profiles folder > Coder Groups). Configure a Default Coder Group: Parameter Value Coder Group Name AudioCodersGroups_0 Coder Name G.729 Coder Name G.711A-law Coder Name G.711U-law Figure 5-16: Configuring a Default Coder Group Version 7.2 AudioCodes Mediant Gateway...
  • Page 30 BroadSoft SIP Trunk Configure PSTN Interface This section describes the configuration of the public switched telephone network (PSTN) related parameters. 5.5.1 Configure PRI Trunk Settings This step shows how to configure the PRI Trunk.  To configure the PRI PSTN interface: Open the Trunk Settings page (Setup menu >...
  • Page 31: Configure Trunk Group Parameters

    > Routing > IP > Tel Routing). Figure 5-19: Configuring Inbound IP Routing Rules Configure a rule for all incoming IP calls, route them to Trunk Group ID 1 (connected to the PBX). Click Apply. Version 7.2 AudioCodes Mediant Gateway...
  • Page 32: Miscellaneous Configuration

    BroadSoft SIP Trunk Miscellaneous Configuration This section describes miscellaneous Mediant gateway configuration. 5.6.1 Configure Supplementary Services This step describes how to configure Hold Format.  To configure Hold Format: Open the Gateway Supplementary Services Settings page (Setup menu > Signaling &...
  • Page 33 To configure Early Media: Open the Media Settings page (Setup menu > Signaling & Media tab > Media folder > Media Settings). From the 'Enable Early Media' drop-down list, select Enable. Figure 5-23: Configuring Early Media Click Apply. Version 7.2 AudioCodes Mediant Gateway...
  • Page 34 BroadSoft SIP Trunk 5.6.4 Configure Gateway Manipulation Set This step describes how to configure the Mediant Gateway outbound manipulation set number.  To configure Gateway Outbound Manipulation Set number: Open the Admin page. Append the case-sensitive suffix ‘AdminPage’ to the device's IP address in your Web browser's URL field (e.g., http://10.15.77.55/AdminPage).
  • Page 35: Check The Sip Trunk Registration Status

    Check IP address configuration (Setup menu > IP Network tab > Core Entities folder > Static Routes) • Check proxy (SIP Trunk) configuration (Setup menu > Signaling & Media tab > SIP Definitions folder > Proxy & Registration) Version 7.2 AudioCodes Mediant Gateway...
  • Page 36: Secure Device Access

    Note: Due to the vast number of potential attacks (such as DDoS), security of your VoIP network should be your paramount concern. The AudioCodes device provides a wide range of security features to support perimeter defense. For recommended security configuration for your AudioCodes device, refer to AudioCodes' Security Guidelines document.
  • Page 37 Connect the E1/T1 trunk cable to the device’s E1/T1 port. Connect the other end of the trunk cable to your PBX switch. Figure 6-1: Mediant 500 Cabling E1/T1 Port Figure 6-2: Mediant 800B Cabling E1/T1 Port Figure 6-2: Mediant 1000B Cabling E1/T1 Port Version 7.2...
  • Page 38 BroadSoft SIP Trunk This page is intentionally left blank. Quick Guide Document #: LTRT-14020...
  • Page 39: Troubleshooting

    Start the syslog on the screen by typing: # debug log Enable SIP call debugging # debug sip 5 Stop Syslog on the screen by typing: # no debug log BT/HIPCOM SIP Trunk AudioCodes Mediant Gateway...
  • Page 40 Website: www.audiocodes.com ©2017 AudioCodes Ltd. All rights reserved. AudioCodes, AC, HD VoIP, HD VoIP Sounds Better, IPmedia, Mediant, MediaPack, What’s Inside Matters, OSN, SmartTAP, User Management Pack, VMAS, VoIPerfect, VoIPerfectHD, Your Gateway To VoIP, 3GX, VocaNom, AudioCodes One Voice and CloudBond are trademarks or registered trademarks of AudioCodes Limited.

This manual is also suitable for:

Mediant 800bMediant 1000b

Table of Contents