System Status Page - Extron electronics Matrix 12800 Series User Manual

Wideband, video, sync, or audio switchers
Hide thumbs Also See for Matrix 12800 Series:
Table of Contents

Advertisement

im Vertrieb von

System Status Page

Refresh system status
Individual BME status
MKP/MCP status
Select DSVP
www.camboard.de
CAMBOARD Electronics
7.
The switcher checks several possibilities, in the following order, and then
responds accordingly:
a.
Does the address include a specific file name, such as
10.13.156.10/file_name.html? If so, the switcher downloads that HTML
page.
b.
Is there a file in the switcher's memory that is named "index.html"?
If so, the switcher downloads "index.html" as the default startup page.
c.
If neither of the above conditions is true, the switcher downloads the
factory-installed default startup page, "nortxe_index.html" (figure 5-2),
also known as the System Status page.
The Matrix 12800 System Status page (figure 5-2) provides an overall view of the
status of the complete Matrix switcher system, encompassing all BMEs and their
active replaceable components. The status Web page automatically updates itself
every few seconds to reflect the latest status of the switcher components.
Figure 5-2 — System status page
For each BME, the System Status page shows the status of the primary and
redundant power supplies, the primary and redundant controller, the fans, the
input cards, and the output cards. Components that are operating properly are
indicated in green, failures are indicated in red, and components that are not
installed are indicated in gray. If a component fails or is removed, the display
shows the change in status the next time it updates.