7.7.4

Current value change

The Axis 1 current feed value (SD1840, SD1841) of a stationary axis is changed to a specified address.
(1) Timing of current value change
When the execution command for start instruction turns on, the specified address is stored in the Axis 1 current
feed value (SD1840, SD1841).
Start instruction
execution command
Axis 1 current feed value
(SD1840, SD1841)
(2) Precautions
If the new current value exceeds the upper limit of the software stroke, "Software stroke limit +" (Axis 1 error
code: 1103) occurs. If the value is smaller than the lower limit of the software stroke, a "Software stroke limit-"
error (Axis 1 error code: 1104) occurs. In these cases, the current value is not changed.
100
OFF
****
ON
Value set for "Positioning address/movement amount"