User Information - Jøtul GF 400 BF CE2 Installation And Operation Instructions Manual

Balanced flue gas stove
Table of Contents

Advertisement

139810_R4 GF 400 BF CE2 7/18

5. User Information

Operating Instructions
Commissioning, Lighting
NOTE! Odours may be present when using the stove for
the first time:
When used for the first time and hot, the appliance
will emit a harmless, non-toxic odour. It is recommended
that the room should be thoroughly ventilated (by
opening doors or windows) during initial use. The gas is
not toxic, but the room should be thoroughly aired out.
During first use, it may take a short time before the gas
tube is cleared of air, but subsequently the appliance
should function as described in the lighting instruction.
Prior to lighting:
• Use a soap and water solution to check all fuel connec-
tions for possible gas leaks. Use a digital gas detector to
check the area around the appliance and at the ceiling
as natural gas is lighter than air and will rise. Any leak
must be eliminated before the appliance is put into
service.If you detect an odor of gas, see Warnings under
Safety Precautions on page 5.
• Do not use the appliance if any part of it has been
submerged in water. Call for service to replace the parts
that have been in water.
TESC Valve Controls Identification
The burner operates in conjunction with a pilot flame
that is automatically lit when there is a call for heat by
actuating either the valve controls or a remote control
handset. The valve and burner controls are located under
the firebox behind the access panel. See Fig. 18, page 16.
1. Master Switch:
Left position (O) - The valve is disconnected from all
power. The burner cannot function. Set the switch to
this position if the appliance will not be used for long
periods.
Right position (I) - The valve is powered and operable.
2. Indicator Lamp:
• Fast flashing - the valve is busy and will not accept
commands.
• Medium Fast flashing - the valve is preparing to start
or restart the burner.
• Slow flashing - the valve has detected an error.
• One short flash every 8 seconds - Low Battery condition.
See Battery Replacement, page 11.
3. Burner Power Button: Powers the burner On and Off.
4. Power Increaser Button: Raises burner flame intensity
through 7 levels .
5. Power Decreaser Button: Lowers flame intensity.
10
Lighting Instructions
WARNING: THIS APPLIANCE
FEATURES ELECTRONIC
!
PILOT IGNITION. DO NOT
ATTEMPT TO LIGHT THE PILOT
MANUALLY.
Lighting the Burner - Manually
1. Slide the white Master Switch to the right (I)
to power the TESC valve.
2. Press the Burner Power button for 1
second and release. The red LED will flash
accompanied by an audible chirp as the pilot
flame ignites. Within approximately 1 to 10
seconds, the burner will light at the medium
level 3.
Operate the burner at this power level for
several minutes to allow the stove and
vent system to thoroughly warm up before
adjusting the power level further.
3. Adjust the burner intensity level by pressing
the Increaser (+) and Decreaser (-) buttons to
achieve the desired heat output.
Turning Off the Appliance - Manually
1. Press and release the Burner Power button.
The burner will extinguish and go into
Standby mode.
Remote Control (Handset) Operation
Refer to the instructions beginning on page 16.
CAUTON: If any flame supervision
device or actuating flame (pilot light)
is extinguished either intentionally or
unintentionally, no attempt should be
made to re-ignite the gas until at least 3
minutes have elapsed.

Advertisement

Table of Contents
loading

Table of Contents