User Information - Jøtul GF 373 BF Installation And Operation Instructions Manual

Balanced flue gas stove;
Table of Contents

Advertisement

139807_R4 GF 373 BF CE 7/17

5. User Information

Operating Instructions
Commissioning, Lighting
NOTE! Odours may be present when using the stove for the
first time:
When used for the first time and hot, the appliance will
emit a harmless, non-toxic odour. It is recommended that
the room should be thoroughly ventilated (by opening doors
or windows) during initial use. The gas is not toxic, but the
room should be thoroughly aired out. During first use, it may
take a short time before the gas tube is cleared of air, but
subsequently the appliance should function as described in
the lighting instruction.
Prior to lighting:
1. Check the area around the appliance for possible gas leaks/
odors. Especially check near the floor, since propane is
heavier than air and would gather close to the floor in the
event of a leakage. (Note: Natural gas is lighter than air and
will gather under the ceiling). If you detect an odor of gas,
see Warnings under Safety Precautions on page 5.
• Do not use the appliance if any part of it has been
submerged in water. Call for service to replace the parts
that have been in water.
Manual Valve Control
The burner operates in conjunction with a pilot flame that
is automatically lit when there is a call for heat by actuating
either the valve controls or a remote control handset. The valve
and burner controls are located under the firebox behind the
access door. See fig. 16.
1. Master Switch:
Left position (O) - The valve is disconnected from all power.
The burner cannot function. Set the switch to this position
if the appliance will not be used for long periods.
Right position (I) - The valve is powered and ready to
operate.
2. Indicator Lamp:
• Fast flashing - the valve is busy and will not accept
commands.
• Medium Fast flashing - the valve is preparing to start or
restart the burner.
• Slow flashing - the valve has detected an error.
One short flash every 8 seconds - Low Battery condition. See
Battery Replacement, page 11.
3. Burner Power Button: Powers the burner On and Off.
4. Power Increaser Button: Raises burner flame intensity through
7 levels .
5. Power Decreaser Button: Lowers flame intensity.
10
Lighting Instructions
!
Lighting the Burner - Manually
1. Slide the white Master Switch to the right
(I) to power the TESC valve.
2. Press the Burner Power button for 1
second and release. The red LED will flash
accompanied by an audible chirp as the
pilot flame ignites. Within approximately
1 to 10 seconds, the burner will light at the
medium level 3.
Operate the burner at this power level for
several minutes to allow the stove and
vent system to thoroughly warm up before
adjusting the power level further.
3. Adjust the burner intensity level by
pressing the Increaser (+) and Decreaser
(-) buttons to achieve the desired heat
output.
Turning Off the Appliance - Manually
1. Press and release the Burner Power button.
The burner will extinguish and go into
Standby mode.
Remote Control (Handset) Operation
Refer to the instructions beginning on
page 18.
CAUTON: If any flame supervision
device or actuating flame (pilot light)
is extinguished either intentionally
or unintentionally, no attempt
should be made to re-ignite the gas
until at least 3 minutes have elapsed.
WARNING: THIS APPLIANCE
FEATURES ELECTRONIC
PILOT IGNITION. DO NOT
ATTEMPT TO LIGHT THE PILOT
MANUALLY.