4-24
3745-XXA 4-24 3746-9X0: 6578 SPIM
Diagnostic Error Code
170-198-XXX
Voltage Sensors test aborted
170-199-XXX
Voltage Sensors test failed, cause
unknown
170-250-XXX
170-251-XXX
Voltage Sensors Voltage limit error
170-254-XXX
Voltage Sensors Voltage Regulator
Module error
175-000-XXX
Thermal Sensors Test Passed
175-0XX-XXX
Thermal Sensors failure
175-195-XXX
Thermal Sensors Test aborted by user
175-196-XXX
Thermal Sensors test halt, error threshold
exceeded
175-197-XXX
Thermal Sensors test warning
175-198-XXX
Thermal Sensors test aborted
175-199-XXX
Thermal Sensors test failed, cause
unknown
175-250-XXX
175-251-XXX
Thermal Sensors limit error
185-000-XXX
Asset Security Test Passed
FRU to replace/action to take
1. If a component is called out, make
sure that it is enabled or
connected.
2. Flash the system and retest.
3. Go to "Undetermined Problems" on
page 3-22.
1. Go to "Undetermined Problems" on
page 3-22.
2. Flash the system and retest.
3. Replace component under function
test.
1. Power supply
2. System board
1. Voltage Regulator Module (VRM)
2. Microprocessor
3. System board
No action
1. Flash system
2. System board
1. Information
2. Restart the test, if you need to.
1. Press F3 to review the log file. See
"Viewing the Test Log" on
page 4-8.
2. Restart the test to reset the log file.
1. Make sure that the component that
is called out is enabled or
connected.
2. Rerun the test.
3. Component that is called out in
warning statement
4. Component under test
1. If a component is called out, make
sure that it is enabled or
connected.
2. Flash the system and retest.
3. Go to "Undetermined Problems" on
page 3-22.
1. Go to "Undetermined Problems" on
page 3-22.
2. Flash the system and retest.
3. Replace component under function
test.
1. Check fans.
2. Check power supply.
3. Microprocessor
4. System board
No action