IBM 3746-900 Installation And Maintenance Manual page 138

Service processor (based on 6578)
Table of Contents

Advertisement

4-20
3745-XXA 4-20 3746-9X0: 6578 SPIM
Diagnostic Error Code
030-197-XXX
SCSI interface test warning
030-198-XXX
SCSI interface test aborted
030-199-XXX
SCSI interface test failed, cause unknown
035-000-XXX
RAID interface Test Passed
035-0XX-XXX
RAID interface Failure
035-195-XXX
RAID interface Test aborted by user
035-196-XXX
RAID interface test halt, error threshold
exceeded
035-197-XXX
RAID interface test warning
035-198-XXX
RAID interface test aborted
035-199-XXX
RAID interface test failed, cause unknown
071-000-XXX
Audio port Interface Test Passed
FRU to replace/action to take
1. Make sure that the component that
is called out is enabled or
connected.
2. Rerun the test.
3. Component that is called out in
warning statement
4. Component under test
1. If a component is called out, make
sure that it is enabled or
connected.
2. Flash the system and retest.
3. Go to "Undetermined Problems" on
page 3-22.
1. Go to "Undetermined Problems" on
page 3-22.
2. Flash the system and retest.
3. Replace component under function
test.
1. No action
1. RAID signal cable
2. RAID device
3. RAID adapter card, if installed
4. System board
1. Information
2. Restart the test, if you need to.
1. Press F3 to review the log file. See
"Viewing the Test Log" on
page 4-8.
2. Restart the test to reset the log file.
1. Make sure that the component that
is called out is enabled or
connected.
2. Rerun the test.
3. Component that is called out in
warning statement
4. Component under test
1. If a component is called out, make
sure that it is enabled or
connected.
2. Flash the system and retest.
3. Go to "Undetermined Problems" on
page 3-22.
1. Go to "Undetermined Problems" on
page 3-22.
2. Flash the system and retest.
3. Replace component under function
test.
No action

Advertisement

Table of Contents
loading

Table of Contents