WPS uses a three-point rigging system. The mechanical load of the array is taken through the side-mounted steel rigging strips which
securely connect one cabinet to the next, while the best possible coupling between cabinets is ensured by means of the rear rigging points
which allow a range of angle adjustment from 0.5° to 10°.
The cabinets are joined using machined quick release lock pins. These have spring loaded ball bearings at the end of the pin which
protrude beyond the outer diameter of the pin thus locking them in place.
To release them, the central button is depressed.
When using the pins to link cabinets, the central button must
again be depressed so the pin can be pushed into position.
It is important to check that the central button does not remain depressed once you have put it in place as this would indicate that the pin
has not been pushed all the way into position and the ball bearings at the end of the pin have not been able to pop out and rigging the pin
in place. If the pin is not locked the array is unsafe. The pin MUST be repositioned until it is securely locked in place.
WPS USER GUIDE V1.0
Copyright © 2019 Martin Audio Ltd.
Pull the pin clear using the wide flange whilst your thumb
depresses the central button.