Manual Start Of Motor/Priming - Pentair Pool Products Nocchi CPS 10 Use And Maintenance Manual

Table of Contents

Advertisement

RIP F
RIP T
ORE P
SCA T
SCA S
FP
TAB
5.4

MANUAL START OF MOTOR/PRIMING

This procedure is applicable when you want to manually start the system or prime the pump.
It is possible to manually start the motor by pressing the following sequence of buttons:
Buttons sequence with pump off
The pump remains on until the last button is pressed
44
Restart type
Parameter used to define how the restarting mechanism
works. If set to FIN, the module will go into a definitive
alarm after the fourth attempt. If sent to CICL, it will
attempt to restart indefinitely using the interval specified
during the fourth attempt.
Intervention time
Waiting time after restarting within which pressure must
return to above the minimum threshold level for lack of
water. (seconds)
Hours running
Number of hours the pump has been running.
Exchange time
Parameter indicating the amount of time a pump must run
for. Once this value has been reached, the pump will stop
and a second pump will commence working. This
parameter is expressed in minutes until it reaches 60,
after which it is expressed in hours. The difference is
indicated by the presence of an "H" for hours and an "M"
for minutes.
Must be set to primary for a unit or for twin pumps.
Exchange
time
Pumps are exchanged once the SCAT parameter has
mode
been reached:
T1: The active pump is switched off first, before the
second pump starts up
T2: The second pump is switched off first, before the first
pump starts-up.
PWM frequency
Frequency of the PWM which controls the motor.
Anti-locking
Amount of time the pump is inactive. Once this amount of
time has expired, the pump will start up for 15 seconds at
maximum frequency. Then, the frequency will be slowly
lowered until the minimum set frequency is obtained. This
parameter is expressed in minutes until it reaches 60,
after which it is expressed in hours. The difference is
indicated by the presence of an "H" for hours and an "M"
for minutes.
Last button pressed for 10 seconds
Page 17 of 30
17 - GB -
FIN
FIN
CICL
15
5
300
N.A.
N.A.
N.A.
0
0
168
1
1
2
15.9
5.1
15.9
0
0
999

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nocchi cps 20

Table of Contents