With the buttons
-
Press "MODE" to move onto changing the day
-
With the buttons
-
To save the values press "SET". The symbol
the screen for a few seconds to show that the data has been saved.
-
Press "MODE" to go back to the pressure screen

5.3.2 SET POINT

DESCR
PARAMETER
MENU
DISPLAY
SET 1
Set Point 1
SET 2
Set Point 2
To access this menu press and release the SET button:
-
During the modification of the set point parameters, the symbol
-
With the buttons
-
SET POINT 1: Pressure desired by the system, the module varies the motor speed to maintain the
system pressure as near as possible to that set. During the regulation of this parameter, the writing
"SET 1" appears.
-
SET POINT 2: Present only if the module was set to function with two set points (SETn = 2", see
"ADVANCED PARAMETERS"). When setting this parameter the display shows SET1 followed by
SET2, proceed to program.
-
x
-
Pres "SET" to confirm. The symbol
a few seconds to show that the data has been saved.
If two SET POINTS are present, it is possible to select the one desired using the "S.P." external contact (see
electrical connections diagram) or the internal clock (see Chapter 5.3).
it is possible to modify the time.
it is possible to modify the day.
NAME
Main pressure value
Secondary pressure value (can be set only if the
parameter SET n = 2)
it is possible to modify the pressure values.
Press the MODE button to go from SET1 (Set-point1) to SET2 (Set-point2)
will disappear. The words "REC" will appear on the screen for
Page 12 of 30
.
will disappear and the words "REC" will appear on
DESCRIPTION
12 - GB -
DEFAULT
MIN
(bar)
(bar)
3
1
2
1
lights up on the display;
MAX
(bar)
8
8
39