Installation
Step
Activity
1
Read the guidelines on preventing electrical interference (see Section 3.3).
2
Connect the processing unit to the sensor head and the lighting unit with the cables.
3
If you do not want to process the result bits READ, MATCH, N_OK via PROFIBUS DP: Connect
the READ, MATCH, N_OK digital outputs as described in Section 6.1.1.
4
Connect the trigger signal via the TRG digital input.
5
If you intend to control the SIMATIC VS 130 with a PLC, connect the other digital inputs and
outputs as described in Section 6.1.1
6
Connect functional ground of the processing unit to chassis ground
(diameter of the ring: M5, cable cross section 1.5 mm
7
Connect the processing unit to the 24 V power supply (2 A).
8
Connect the PC / PG via the RS-232 interface. The PC / PG is required only for setting up the
sensor.
Optional (not supplied with the package):
RS-232 cable 5 m long, connectors prefitted at SIMATIC VS 130 end and PLC/PC end
(pinning, see Appendix A.5).
Note
The DC load power supply must meet the following requirements:
Only low voltage less than or equal to 24 V DC safely isolated from the power
supply network must be used for the load current supply. Safe isolation can be
implemented, for example, by adhering to the specifications in
VDE 0100-410 / HD 384-4-41 S2 / IEC 60364-4-41
(functional low voltage with safe isolation) or
VDE 0805 / EN 60950 / IEC 60950
(as safety extra-low voltage SELV) or VDE 0106 Part 101.
Note
The supply chassis of the I/O and CPU must be connected to the supply chassis of
the processing unit.