F-Code Transmission And Polling; F-Code Transmission - Muratec MFX-1500 Operating Instructions Manual

Plain-paper fax machine
Hide thumbs Also See for MFX-1500:
Table of Contents

Advertisement

6
Use the numeric keypad to enter your F-Code's four-digit passcode. Here
we've entered 2345:
03:Print F-Code Doc.
F-Code Passcode:2345
7
Press
.
ENTER
• If you've entered the correct passcode, your fax machine will print all
documents in — and then erase them from — the mailbox.
• If you've entered an incorrect passcode, your fax machine will refuse to
print the document.

F-Code transmission and polling

With F-Code, your machine — in addition to sending Muratec-proprietary
SecureMail (pages 2.39–2.42) and performing database polling (pages 2.30–2.31)
from only other Muratec models — can send secure transmissions to, and perform
database polling from, other makers' machines, as well. You may accomplish such
transmissions in either of two ways:
• Programmable one-touch key (see pages 2.68–2.70)
• Direct entry of the
-
sub-address and password, which is what we will now
ITU
T
describe.
Whether you are sending to or polling from another machine, you obviously must
know the correct sub-address on the receiving machine, as well as the password if
that sub-address has one. (This is analogous to how, with Muratec SecureMail, you
must know the correct SecureMail mailbox number and password on the remote
Muratec fax.)
Note: For F-Code communication to occur, three things must be true:
• The remote fax machine must support
capabilities.
• A mailbox with an
-
sub-address must exist on the remote fax. (It doesn't
ITU
T
have to have a password. If the other machine hasn't at least one box with a sub-
address, F-Code communication will be impossible).
• You must know the
-
sub-address and (if applicable) password information
ITU
T
for the mailbox on the remote machine.

F-Code transmission

1.
/
Press
to change to Fax mode, if necessary.
COPY
FAX
2.
Insert the document.
3.
Adjust resolution and contrast if necessary.
-
sub-addressing (and password)
ITU
T
4.
If you wish to toggle between transmission from the feeder and transmission
from memory, press
MEMORY TRANSMIT
Note: This toggle affects only a transmission from the
from the
is always memory transmission.
FBS
5.
Press
COMMUNICATION OPTIONS
7.F-Code TX
Comm.Option/Enter
6.
Press
.
ENTER
Enter Sub-Address
_
7.
Use the numeric keypad to enter the appropriate sub-address number. In this
example, we've entered 123456.
Enter Sub-Address
123456_
Note: If you make a mistake, press
one-digit number.
8.
Press
. The display will show:
ENTER
Enter Password
_
Note: If you know that this sub-address does not have a password, skip to
step 10.
9.
Use the numeric keypad to enter the appropriate password number. In this
example, we've entered 654321.
Enter Password
654321_
Note: If you make a mistake, press
one-digit number.
10.
Press
. The display will show:
ENTER
Enter Fax Number
_
11.
Enter the fax number either by pressing a one-touch key, entering a speed-dial
number or dialling from the numeric keypad. Do not press
Beyond the basics
.
. Transmission
ADF
seven times and then press
.
ENTER
to back up, then enter the correct
CANCEL
to back up, then enter the correct
CANCEL
.
START
2.59

Advertisement

Table of Contents
loading

Table of Contents