Operation
Horizontal phase adjustment
1. Select the pan/tilt head system using the
CONTROL/PREVIEW MONITOR OUT SEL button.
2. Connect the external synchronizing signal and the video
signal from the currently selected pan/tilt head system
(when using the cable compensation unit, the
corresponding Y/VIDEO OUT terminal) to the 2CH
oscilloscope.
3. Press the MENU button, turn the menu setting control
(main), and set it so that the G/L SETTING item appears
at the top of the LCD panel.
G G / / L L S S E E T T T T I I N N G G
4. Press the OK button.
The following item appears on the LCD panel.
H H P P H H A A S S E E
5. Using the menu setting control (R), align the horizontal
phase of the video signal waveforms on the oscilloscope
and external sync signal waveforms.
Align the horizontal phase.
6. Select the next pan/tilt head system using the
CONTROL/PREVIEW MONITOR OUT SEL button, and
continue adjusting the horizontal phase in each system
concerned.
O O K K K K e e y y
n
± ± 0 0
External sync
signal
Video signal
23