Connecting Power - Siemens RUGGEDCOM RSG2300P Installation Manual

Hide thumbs Also See for RUGGEDCOM RSG2300P:
Table of Contents

Advertisement

Chapter 2
Installing Device
Figure 5: Failsafe Alarm Relay Wiring
1. Normally Open    2. Common    3. Normally Closed
Section 2.6

Connecting Power

The RUGGEDCOM RSG2300P supports a single AC or DC power supply, and a separate 48 VDC power supply for
PoE ports.
The RUGGEDCOM RSG2300P can be equipped with either a screw-type or pluggable terminal block, which
provides power to the AC/DC power supply and PoE ports. The screw-type terminal block is installed using Phillips
screws and compression plates, allowing either bare wire connections or crimped terminal lugs. Use #6 size ring
lugs for secure, reliable connections under severe shock or vibration.
CAUTION!
Electrical hazard – risk of damage to the device. Disconnect the device from the power supply if power
input is above or below the specified input range. For more information, refer to
Supply
Specifications".
NOTE
• Use only #16 gage copper wiring when connecting terminal blocks.
• For 110/230 VAC rated equipment, an appropriately rated AC circuit breaker must be installed.
• A circuit breaker is not required for 12, 24 or 48 VDC rated power supplies.
• It is recommended to provide a separate circuit breaker for each power supply module.
• Equipment must be installed according to applicable local wiring codes and standards.