  • Page 1 Installation Manual SIMATIC NET Rugged Ethernet Switches RUGGEDCOM RS416PF Edition 04/2021 https://www.siemens.com...
  • Page 2 Preface Introduction Installing Device SIMATIC NET Device Management Rugged Ethernet Switches RUGGEDCOM RS416PF Communication Ports Technical Specifications Installation Manual Certification 04/2021 C79000-G8976-1355-04...
  • Page 3 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 4: Table Of Contents

    Accessing Documentation ....................... v Registered Trademarks ......................v Warranty ..........................v Training ..........................vi Customer Support ........................vi Contacting Siemens ....................... vii Introduction ........................... 1 Feature Highlights ....................1 Description ......................2 Required Tools and Materials ................. 4 Decommissioning and Disposal ................4 Cabling Recommendations ..................
  • Page 5 European Union (EU) ..................41 6.1.3 FCC ........................42 6.1.4 FDA/CDRH ......................42 6.1.5 ISED ........................43 6.1.6 ISO ........................43 6.1.7 RoHS ........................43 6.1.8 Other Approvals ....................43 EMC and Environmental Type Tests ..............44 RUGGEDCOM RS416PF Installation Manual, 04/2021, C79000-G8976-1355-04...
  • Page 6: Preface

    Warranty Siemens warrants this product for a period of five (5) years from the date of purchase, conditional upon the return to factory for maintenance during the warranty term. This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void.
  • Page 7: Training

    Siemens Sales representative. Customer Support Customer support is available 24 hours, 7 days a week for all Siemens customers. For technical support or general information, contact Siemens Customer Support through any of the following methods: Online Visit http://www.siemens.com/automation/support-request...
  • Page 8: Contacting Siemens

    Preface Contacting Siemens • Contact a local Siemens representative from Sales, Technical Support, Training, etc. • Ask questions or share knowledge with fellow Siemens customers and the support community Contacting Siemens Address Siemens AG Industry Sector 300 Applewood Crescent Concord, Ontario...
  • Page 9 Preface Contacting Siemens viii RUGGEDCOM RS416PF Installation Manual, 04/2021, C79000-G8976-1355-04...
  • Page 10: Introduction

    The RUGGEDCOM RS416PF also features a wide operating temperature range of -40 to 85 °C (-40 to 185 °F) allowing it to be installed in virtually any location.
  • Page 11: Description

    CSA/UL 62368-1 safety approved to 85 °C (185 °F) Description The RUGGEDCOM RS416PF features various ports, controls and indicator LEDs on the display panel for connecting, configuring and troubleshooting the device. The display panel can be located on the rear, front or top of the device, depending on the mounting configuration.
  • Page 12 RS-232 Serial Console Port (RJ45) Figure 1.1 RUGGEDCOM RS416PF Communication Ports Ports for communicating with other devices or accessing the RUGGEDCOM RUGGEDCOM RS416PF operating system are described in "Communication Ports (Page 25)". Port Status Indicator LEDs Port status indicator LEDs indicate the operational status of each port, dependent on the currently selected mode.
  • Page 13: Required Tools And Materials

    "Connecting to the Device (Page 23)". Required Tools and Materials The following tools and materials are required to install the RUGGEDCOM RS416PF: Tools/Materials Purpose AC power cord (16 AWG) For connecting power to the device.
  • Page 14: Supported Fiber Optic Cables

    The PTP module can only be installed in slot 5. For more information, refer to "Communication Ports (Page 25)". TTL OUT Port TTL IN Port Figure 1.2 PTP Module For more information about the BNC ports, refer to "BNC Ports (Page 31)". RUGGEDCOM RS416PF Installation Manual, 04/2021, C79000-G8976-1355-04...
  • Page 15: Supported Time Synchronization Sources

    GPS receiver at each node or for which GPS signals are inaccessible. The RUGGEDCOM RS416PF only supports ordinary clock mode. An ordinary clock can be configured as either a Grandmaster Clock (GM) or a Slave Clock (SC) within the master-slave hierarchy.
  • Page 16: Ieee 1588 Support

    (VL) the connected devices see is greater than the minimum required voltage. 1.6.3 IEEE 1588 Support RUGGEDCOM RS416PF supports various IEEE 1588 time synchronization capabilities and provides synchronization in 2-step mode. This mode supports the following clock types: •...
  • Page 17 Introduction 1.6.3 IEEE 1588 Support RUGGEDCOM RS416PF Installation Manual, 04/2021, C79000-G8976-1355-04...
  • Page 18: Installing Device

    This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void. Changes or modifications not expressly approved by Siemens AG could invalidate specifications, test results, and agency approvals, and void the user's authority to operate the equipment.
  • Page 19: General Procedure

    Inspect the package for damage before opening it. Visually inspect each item in the package for any physical damage. Verify all items are included. Note If any item is missing or damaged, contact Siemens for assistance. RUGGEDCOM RS416PF Installation Manual, 04/2021, C79000-G8976-1355-04...
  • Page 20: Mounting The Device

    2.3.1 Mounting the Device to a Rack For rack mount installations, the RUGGEDCOM RS416PF can be equipped with rack mount adapters pre-installed at the front or rear of the chassis. Additional adapters are provided to further secure the device in high-vibration or seismically active locations.
  • Page 21: Mounting The Device On A Din Rail

    2.3.2 Mounting the Device on a DIN Rail For DIN rail installations, the RUGGEDCOM RS416PF can be equipped with panel/DIN rail adapters pre-installed on each side of the chassis. The adapters allow the device to be slid onto a standard 35 mm (1.4 in) DIN rail.
  • Page 22: Mounting The Device To A Panel

    2.3.3 Mounting the Device to a Panel For panel installations, the RUGGEDCOM RS416PF can be equipped with panel/DIN rail adapters pre-installed on each side of the chassis. The adapters allow the device to be attached to a panel using screws.
  • Page 23: Connecting The Failsafe Alarm Relay

    Control of the failsafe relay output is configurable through RUGGEDCOM RS416PF . One common application for this relay is to signal an alarm if a power failure occurs. For more information, refer to the RUGGEDCOM RS416PF User Guide for the RUGGEDCOM RS416PF.
  • Page 24: Grounding The Device

    Figure 2.4 Failsafe Alarm Relay Wiring Grounding the Device The RUGGEDCOM RS416PF chassis ground terminal uses a #6-32 screw. It is recommended to terminate the ground connection with a #6 ring lug and torque it to 1.7 N·m (15 lbf·in). Stainless Steel Stud...
  • Page 25: Connecting Power

    Installing Device 2.6 Connecting Power Connecting Power The RUGGEDCOM RS416PF supports a single high AC or low DC power supply, and a separate 48 VDC power supply for PoE ports. The RUGGEDCOM RS416PF can be equipped with either a screw-type or pluggable terminal block, which provides power to the AC/DC power module and PoE ports.
  • Page 26 Install the supplied metal jumper between terminals 2, 4 and 6 to connect the surge ground terminals to the chassis ground terminal. The surge ground terminals are used as the ground conductor for all surge and transient suppression circuitry internal to the unit. RUGGEDCOM RS416PF Installation Manual, 04/2021, C79000-G8976-1355-04...
  • Page 27: Connecting External Poe Power

    Install the terminal block cover. 2.6.2 Connecting External PoE Power The RUGGEDCOM RS416PF supports up to four 10/100Base-TX Power-over-Ethernet (POE) Ports that require power from an external source. Note For IEC 61850 compliance, use an IEC 61850 compliant PoE power supply with power cabling no longer than 3 m (118 in).
  • Page 28: Wiring Examples

    Make sure the supplied terminal block cover is always installed before the device is powered. Install the terminal block cover. 2.6.3 Wiring Examples The following illustrate how to connect power to single and dual power supplies. RUGGEDCOM RS416PF Installation Manual, 04/2021, C79000-G8976-1355-04...
  • Page 29 Installing Device 2.6.3 Wiring Examples Figure 2.8 Single AC Power Supply Figure 2.9 Single DC Power Supply RUGGEDCOM RS416PF Installation Manual, 04/2021, C79000-G8976-1355-04...
  • Page 30 Installing Device 2.6.3 Wiring Examples Figure 2.10 DC Power Supply and External PoE Power Supply Figure 2.11 AC Power Supply and External PoE Power Supply RUGGEDCOM RS416PF Installation Manual, 04/2021, C79000-G8976-1355-04...
  • Page 31 Installing Device 2.6.3 Wiring Examples RUGGEDCOM RS416PF Installation Manual, 04/2021, C79000-G8976-1355-04...
  • Page 32: Device Management

    This section describes how to connect to and manage the device. Connecting to the Device The following describes the various methods for accessing the RUGGEDCOM RS416PF console and Web interfaces on the device. For more detailed instructions, refer to the RUGGEDCOM RS416PF User Guide for the RUGGEDCOM RS416PF.
  • Page 33: Configuring The Device

    Communication Ports Connect any of the available Ethernet ports on the device to a management switch and access the RUGGEDCOM RS416PF console and Web interfaces via the device's IP address. For more information about available ports, refer to "Communication Ports (Page 25)".
  • Page 34: Communication Ports

    Communication Ports The RUGGEDCOM RS416PF can be equipped with various types of communication ports to enhance its abilities and performance. Each communication port type has a specific place in the RUGGEDCOM RS416PF chassis. Slot 1 Slot 2 Slot 3 Slot 4...
  • Page 35: Poe Ports

    Port Specifications (Page 36)". PoE Ports The RUGGEDCOM RS416PF supports up to four 10/100Base-TX Power over Ethernet (POE) ports powered by an external power supply. Each port complies with the IEEE 802.3af standard and features auto-sensing and automatic power off when cables are removed.
  • Page 36: Fiber Optic Ethernet Ports

    60 W, to prevent exceeding the power budget, port priorities can be set via the RUGGEDCOM RS416PF operating system to disable low priority ports when demand is too high. Ports can also be enabled/disabled and placed on a power schedule to conserve power.
  • Page 37: Serial Ports

    Ethernet Port Specifications (Page 36)". Serial Ports The RUGGEDCOM RS416PF supports serial cards with fiber serial ST (Straight Tip) connectors, RS232/RS485/RS422 DB9 serial ports or RS232/RS485/RS422 RJ45 serial ports. Serial DB9 and RJ45 ports can be run in RS232, RS485 or RS422 mode. They can also be ordered with IRIG-B time code support.
  • Page 38 Pins 1, 4 and 6 and pins 7 and 8 are connected internally. In RS232 mode, these pins enter a high impedance state. A DTE that asserts RTS will see CTS asserted. However, the device will not perform hardware flow control. RUGGEDCOM RS416PF Installation Manual, 04/2021, C79000-G8976-1355-04...
  • Page 39 Pins 1, 2 and 3 and pins 7 and 8 are connected internally. In RS232 mode, these pins enter a high impedance state. A DTE that asserts RTS will see CTS asserted. However, the device will not perform hardware flow control. RUGGEDCOM RS416PF Installation Manual, 04/2021, C79000-G8976-1355-04...
  • Page 40: Bnc Ports

    TTL IN Port Figure 4.13 PTP Module Inputs are controlled by RUGGEDCOM RS416PF and only one can be active at any time. For information about activating an input, refer to the RUGGEDCOM RUGGEDCOM RS416PF User Guide for the RUGGEDCOM RS416PF. The color of the Sync LED on the front panel of the PTP module indicates the status of the incoming timing signal: •...
  • Page 41: Connecting Multiple Rs485 Devices

    • The twisted pair should be terminated at each end of the chain. The following shows the recommended RS485 wiring. 120Ω 10nF 120Ω 10nF RUGGEDCOM RS416PF Common (Isolated Ground) Negative Positive Shield to Earth (Connected At a Single Point) RUGGEDCOM RS416PF...
  • Page 42 Communication Ports 4.6 Connecting Multiple RS485 Devices RS485 Devices (32 Total) Figure 4.14 Recommended RS485 Wiring RUGGEDCOM RS416PF Installation Manual, 04/2021, C79000-G8976-1355-04...
  • Page 43 Communication Ports 4.6 Connecting Multiple RS485 Devices RUGGEDCOM RS416PF Installation Manual, 04/2021, C79000-G8976-1355-04...
  • Page 44: Technical Specifications

    Fuse Rating Consumption Minimum Maximum 48 VDC 37 VDC 72 VDC 2 A(T) 68 W (T) denotes time-delay fuse. Failsafe Relay Specifications Maximum Switching Voltage Rated Switching Current 30 VAC 0.3 A, 1.0 A RUGGEDCOM RS416PF Installation Manual, 04/2021, C79000-G8976-1355-04...
  • Page 45: Copper Ethernet Port Specifications

    Shielded or unshielded. Auto-crossover and auto-polarity. RMS 1 minute. Fiber Optic Ethernet Port Specifications The following details specifications for the fiber optic Ethernet ports that can be equipped on the RUGGEDCOM RS416PF. 10Base-FL Ethernet Optical Ports Power Connector Cable Tx λ...
  • Page 46: Serial Port Specifications

    1200 to 230400 kbps RJ45 2.5 kV Fiber Serial Ports Typical Optical Mode Connector Cable Size Distance (km) Wavelength (nm) 50/125 Multimode 62.5/125 IRIG-B Port Specifications IRIG-B PWM Input Specifications Parameter Specification Input Voltage TTL-Compatible RUGGEDCOM RS416PF Installation Manual, 04/2021, C79000-G8976-1355-04...
  • Page 47: Operating Environment

    100 mA Output Voltage (V TTL-Compatible Output Impedance (R 50 Ω Operating Environment The RUGGEDCOM RS416PF is rated to operate under the following environmental conditions. Ambient Operating -40 to 85 °C (-40 to 185 °F) Temperature Ambient Storage Temperature -40 to 85 °C (-40 to 185 °F)
  • Page 48 Technical Specifications 5.10 Dimension Drawings 438.15 Figure 5.1 Overall Dimensions RUGGEDCOM RS416PF Installation Manual, 04/2021, C79000-G8976-1355-04...
  • Page 49 Technical Specifications 5.10 Dimension Drawings 479.30 11.68 461.01 21.08 32.64 4.57 Figure 5.2 Rack Mount Dimensions 486.4 476.3 10.4 11.7 Figure 5.3 Panel and DIN Rail Mount Dimensions RUGGEDCOM RS416PF Installation Manual, 04/2021, C79000-G8976-1355-04...
  • Page 50: Certification

    Information Technology Equipment - Safety - Part 1: General Requirements The device is marked with a CSA symbol that indicates compliance with both Canadian and U.S. requirements. A copy of the CSA Certificate of Compliance is available via Siemens Industry Online Support at https://support.industry.siemens.com/cs/ww/en/view/109476557. 6.1.2...
  • Page 51: Fcc

    Safety of Laser Products – Equipment Classification and Requirements The device is marked with a CE symbol and can be used throughout the European community. A copy of the EU Declaration of Conformity is available via Siemens Industry Online Support at https://support.industry.siemens.com/cs/ww/en/view/109482109. 6.1.3 This device has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules.
  • Page 52: Ised

    Title 21 Code of Federal Regulations (CFR) – Chapter I – Sub-chapter J – Radiological Health 6.1.5 ISED This device is declared by Siemens AG to meet the requirements of the following ISED (Innovation Science and Economic Development Canada) standard: • CAN ICES-3 (A)/NMB-3 (A) 6.1.6...
  • Page 53: Emc And Environmental Type Tests

    • IEC 61000-6-2 Electromagnetic Compatibility (EMC) – Part 6-2: Generic Standards – Immunity for Industrial Environments EMC and Environmental Type Tests The RUGGEDCOM RS416PF has passed the following EMC and environmental tests. IEC 61850-3 Type Tests Test Description Test Levels...
  • Page 54 5 kV   ports Siemens specified severity level. IEEE 1613 EMC Immunity Type Tests Note The RUGGEDCOM RS416PF meets Class 2 requirements for an all-fiber configuration and Class 1 requirements for copper ports. Description Test Levels Enclosure Contact ± 8 kV Enclosure Air ±...
  • Page 55 Test Db 95% (non-   Heat, Cyclic) condensing), 55 °C (131 °F), 96 hours IEC 60068-2-6 Vibration 2 g @ 10-150 Hz Class 2 IEC 60068-2-27 Shock 30 g @ 11 ms Class 2 RUGGEDCOM RS416PF Installation Manual, 04/2021, C79000-G8976-1355-04...
  • Page 56 Further Information Siemens RUGGEDCOM https://www.siemens.com/ruggedcom Industry Online Support (service and support) https://support.industry.siemens.com Industry Mall https://mall.industry.siemens.com Siemens AG Digital Industry Process Automation Postfach 48 48 90026 NÜRNBERG GERMANY...