Connecting Ac Or Dc Power - Siemens RUGGEDCOM RSG2300P Installation Manual

Hide thumbs Also See for RUGGEDCOM RSG2300P:
Table of Contents

Advertisement

RUGGEDCOM RSG2300P
Installation Guide
Section 2.6.1

Connecting AC or DC Power

To connect a single high AC, high DC or low DC power supply to the device, do the following:
CAUTION!
Electrical hazard – risk of damage to equipment. Before testing the dielectric strength (HIPOT) in the
field, remove the metal jumper. This metal jumper connects transient suppression circuitry to chassis
ground and must be removed in order to avoid damage to transient suppression circuitry during
testing.
CAUTION!
Electrical hazard – risk of damage to equipment. Do not connect AC power cables to a DC power supply
terminal block. Damage to the power supply may occur.
NOTE
Terminals 5 and 7 (POWER 2) are reserved for the external PoE power supply. For information about
connecting the external PoE power supply, refer to
1.
Remove the terminal block cover.
2.
Identify the internal power module (POWER 1 or POWER 2) appropriate for the power supply (AC or DC).
3.
Use these screws along with #6 ring lugs to secure the wires to the terminal block.
NOTE
For wiring options, refer to
4.
Connect the positive wire from the power source to the positive/live (+/L) terminal on the terminal block.
1
3
Figure 6: Terminal Block Wiring
1. Screw-Type Terminal Block    2. Pluggable Terminal Block    3. Jumper    4. Positive/Live (+/L) Terminal    5. Negative/Neutral (-/N)
Terminal (-/N)    6. Surge Ground Terminal    7. Chassis Ground Terminal
5.
Connect the negative wire from the power source to the negative/neutral (-/N) terminal on the terminal block.
Connecting AC or DC Power
Section 2.6.3, "Wiring
4
5
4
5
6
7
6
Section 2.6.2, "Connecting External PoE
Examples".
6
7
6
4
5
4
5
3
Chapter 2
Installing Device
Power".
2
13

Advertisement

Table of Contents
loading

Table of Contents