Fujitsu PRIMERGY TX150 S6 Operating Manual page 71

Hide thumbs Also See for PRIMERGY TX150 S6:
Table of Contents

Advertisement

Starting up and operation
Hard disk drive indicators
1
Figure 25: Indicators on the 3.5 inch and 2.5 inch HDD modules
LED
HDD FAULT (in conjunction with a disk array controller)
orange
SAS server variant
– Does not light: no HDD error
– Lit: HDD Faulty or Rebuild Stopped (drive defective/needs
replacing, drive failed, drive deactivated by software or the
HDDmodule is not correctly inserted)
– Slow flashing: HDD Rebuild (the data is being restored after
changing a drive)
– Fast flashing: HDD Identify
SATA server variant
– Does not light: no HDD error
– Lit: HDD Faulty or Rebuild Stopped (drive defective/needs
replacing, a rebuild process was stopped or the HDDmodule is
not correctly inserted)
– Slow flashing: HDD Rebuild (the data is being restored after
changing a drive)
– Fast flashing: HDD Identify
LED
HDD BUSY
green
– Lit: HDD in active phase (drive active, drive being accessed)
– Does not light: HDD inactive
TX150 S6
2
Operating Manual
Controls and indicators
1
2
71