Rack Mounting Barrier Boxes - Avaya IP Office Essential Edition PARTNER Version Reference Manual

Hide thumbs Also See for IP Office Essential Edition PARTNER Version:
Table of Contents

Advertisement

Main Building
· RJ11: Connect to PHONE (POT) port on the
Phone module using cable supplied with the
barrier box.
· RJ45: Connect to the secondary building
barrier box via primary protection in both
buildings.
· Center Screw: Connect to main building
protective ground (or ground terminal of
Barrier Box Rack Mounting Kit). Use 18AWG
(minimum) wire with a green and yellow
sleeve.
· Right-Hand Screw: Connect to ground point
on Phone module using ground cable supplied
with barrier box.
Wires from external telephone going directly to the barrier boxes must be kept apart, that is not routed in the same
bundle:
IP Office Barrier Boxes

4.7.3 Rack Mounting Barrier Boxes

Where more than 3 Phone Barrier Boxes are used they must be rack mounted. The Barrier Box Rack Mounting Kit (Part
number 700293905) supports up to 8 Phone Barrier Boxes.
1. Unscrew the two screws arranged diagonally at the front of each barrier box and use these same screws to reattach
the barrier box to the rack mounting strip.
2. Each barrier box is supplied with a solid green ground wire connected to its functional ground screw. Remove and
discard this wire. Connect a green/yellow ground wire to the protective earth screw in the center of the Point on the
back of the Barrier Box.
PARTNER® Version, Installation and Reference Manual
IP Office Essential Edition
System Component Details: Out of Building Telephone Installations (COPY)
IP Office 500 Phone Barrier Box (81V)
Use with Phone V1 module. Includes an RJ45 to RJ11 cable and a
functional earth lead.
IP Office 500 Phone Barrier Box V2 (101V)
Use with Phone V2 module. Includes an RJ45 to RJ11 cable and a
functional earth lead.
Barrier Box Rack Mounting Kit
Barrier Box
Secondary Building
· RJ11: Connect to analog phone.
Cable not supplied.
· RJ45: From main building via
primary protection in both buildings.
· Center Screw: Connect to main
building protective ground. Use
18AWG (minimum) wire with a green
and yellow sleeve.
· Right-Hand Screw: Not used.
Part number
700293897
700385495
700293905
Page 73
- Issue 1a (30 January 2010)