Grounding; Rack Mounting - Avaya IP Office Essential Edition PARTNER Version Reference Manual

Hide thumbs Also See for IP Office Essential Edition PARTNER Version:
Table of Contents

Advertisement

Expansion Interconnect Cable
LAN Cable
The table below details the maximum total cable distances for DS and analog extensions using different cable types.
Telephone
1400 Series
T3 Series (Upn)
Analog Phones

3.2.7 Grounding

Use of ground connections reduces the likelihood of problems in most telephony and data systems. This is especially
important in buildings where multiple items of equipment are interconnected using long cable runs, for example phone
and data networks.
All IP Office control units and external expansion modules must be connected to a functional ground. In some cases, such
as ground start trunks, in addition to being a protective measure this is a functional requirement for the equipment to
operate. In other cases it may be a locale regulatory requirement and or a necessary protective step, for example areas
of high lightning risk.
WARNING
·
During installation do not assume that ground points are correctly connected to ground. Test ground points before
relying on them to ground connected equipment.
The ground point on IP Office control units and external expansion modules are marked with a
Ground connections to these points should use a 14 AWG solid wire with either a green sleeve for a functional ground or
green and yellow sleeve for a protective ground.
· Additional protective equipment
In addition to grounding, additional protective equipment will be required in the following situations. Refer to
Building Telephone
Installations".
· On any Digital Station or Phones external expansion module connected to an extension located in another building.

3.2.8 Rack Mounting

PARTNER® Version, Installation and Reference Manual
IP Office Essential Edition
Connects the control unit to expansion
modules (except WAN3 modules). RJ45 to
RJ45. Blue.
Connects from IP Office LAN ports to IP
devices. RJ45 to RJ45. Grey.
Unshielded Twisted-Pair (UTP) - 50nf/Km
AWG22
(0.65mm)
1000m/3280'.
1000m/3280'.
1000m/3280'.
1000m/3280'.
1000m/3280'.
1000m/ 3280'.
The IP Office 500v2 control unit and IP Office 500 external
expansion units can be rack mounted if required into 19-inch rack
systems. This requires an IP Office 500 Rack Mounting Kit (SAP
700429202) for each unit.
The kit includes:
As indicated in the diagram following, the rack mounting bracket
can be used in several positions on the unit.
AWG24
AWG26
(0.5mm)
(0.4mm)
400m/1310'.
400m/1310'.
400m/1640'.
· A rack mounting bracket and screws for attachment of the
bracket to the unit
· Nuts and bolts for rack attachment.
· Brackets and cable ties for cable tidying.