139919_GI 545 DV and DV MV 5/19
7.4 Optional Controls Installation
7.4.1 Remote Control Kit 158103
Contents:
• Remote Receiver / battery box
• Remote Transmitter
• 4, AA Receiver batteries
• 2, AAA Transmitter batteries
1. Insert the AAA batteries into the Receiver box.
2. Insert the AA batteries into the Remote Transmitter.
3. Remove the protective film from the Velcro® adhesive
pad on the Receiver box and set the box on the floor
within the steel housing to the left of the gas control
valve. See fig. 10.1, #15-16, page 30.
4. Connect the Receiver leads to the valve terminal
block as shown in fig. 7.7.
See the Operation Instructions included with the kit for
complete information regarding features and use of the
remote transmitter and receiver units.
7.4.2 Wall Thermostat
• Use only a 750 millivolt, DC two-wire circuit wall
thermostat. Follow the manufacturerer's installation
instructions.
• Use a minimum 16 gauge wire up to a maximum
length of 35 feet (10.67m) for connection to the
fireplace.
• The thermostat should be placed in the same room as
the heater, typically 5 feet (152 cm) off the floor. Avoid
drafty areas or any area that may affect the accuracy
of the thermostat.
Thermostat Connection
• Remove the fireplace Burner Control face plate with
removal of th e upper two #8 hex head screws.
• Connect each thermostat lead to either of the two
open terminal block connectors located on the back of
the control panel. Do not overtighten the connections.
See fig. 7.7.
• At the thermostat, connect the leads to the two
connection screws on the thermostat base plate
according to the manufacturer's instructions.
18
Thermostatic Operation
Follow the accessory manufacturerer's operation
instructions.
1. Set the fireplace burner mode switch to the STAT
position for either remote or wall thermostat
control.
2. Light the pilot following the instructions found
in this manual and on the appliance rating plate.
When the pilot is lit, the burner will respond to
calls for heat either thermostatically or by remote
transmitter.
THERMOPILE
TH
TP
TH
TP
VALVE
TERMINAL
BLOCK
Figure 7.7. Accessory control wiring diagram.
ROCKER
SWITCH
ON
OFF
STAT
OPTIONAL
THERMOSTAT
or
REMOTE
CONTROL

Advertisement