Installing the Cable Connectors
Installing the Cable Connectors
Figure 31: T1/E1 Cable Connector
One end of the cable (see the figure above) has a 68-pin connector that plugs into the T1/E1 interface module
and the other end of the cable with a 68-pin connector is connected to a RJ48, AMP64 or a DIN patch panel.
Use the thumbscrews on either side of the connector to secure the cable to the interface.
T1/E1 Cable Connectors
Figure 32: T1/E1 Cable Connector
One end of the cable (see the figure above) has a 68-pin connector that plugs into the T1/E1 interface module
and the other end of the cable with a 68-pin connector is connected to a RJ48, AMP64 or a DIN patch panel.
Use the thumbscrews on either side of the connector to secure the cable to the interface.
Patch Panel cables
The patch panel cable connects the interface modules with the patch panel.
Each cable connects one VHDCI connector on the interface module to the connector on the patch panel. A
set of three cables is required to connect one interface module to one 48-port patch panel.
The following table shows details of the patch panel cables:
Patch Panel Cable
CABLE-16TDM-C
Note
CABLE-16TDM-C-R is not supported in Cisco IOS XE Release 3.18.06v.S.
Installing the Cisco NCS 4216
56
Description
16-port cable for TDM CEM Interface Module, no redundancy, 10 feet in length