Installing the Cisco NCS 4216
PID
PWR-CAB-AC-USA
PWR-CAB-AC-AUS
PWR-CAB-AC-EU
PWR-CAB-AC-ITA
PWR-CAB-AC-SA
PWR-CAB-AC-UK
PWR-CAB-AC-ISRL
PWR-CAB-AC-CHN
PWR-CAB-AC-BRA
PWR-CAB-AC-SUI
PWR-CAB-AC-JPN
PWR-CAB-AC-IND
PWR-CAB-AC-ARG
Activating the AC Power Supply
Follow these steps to activate the AC power supply:
Procedure
Step 1
Plug the power cord into the power supply.
Step 2
Connect the other end of the power cord to an AC-input power source.
Step 3
Verify power supply operation by checking that the power supply LEDs are in the following states:
• INPUT OK LED is green
• OUTPUT FAIL LED is green
Step 4
If the LEDs indicate a power problem, see the
Step 5
If you are installing a redundant power supply, repeat these steps for the second power source.
Note
Description
Power Cord for AC V2 Power Module (USA), NEMA L6-20P
Power Cord for AC V2 Power Module (Australia), AS 3112
Power Cord for AC V2 Power Module (Europe), CEE 7/7
Power Cord for AC V2 Power Module (Italy), CEI-23-50
Power Cord for AC V2 Power Module (South Africa), SABS 164
Power Cord for AC V2 Power Module (UK), EN 60309-2
Power Cord for AC V2 Power Module (Israel), SI 32
Power Cord for AC V2 Power Module (China), GB2099.1/GB1002
Power Cord for AC V2 Power Module (Brazil), NBR 14136
Power Cord for AC V2 Power Module (Swiss), SEV 1011
Power Cord for AC V2 Power Module (Japan), JIS C8303
India AC Power Cord for Cisco NCS4200, IS:1293
AC POWER CORD, WIRE HARNESS, Argentina, IRAM 2073, IEC60320
C21, ST, 4M, 30 AWG, STRANDED, 250.0 V, 16.0 A
If you are installing a redundant AC power supply, ensure that each power supply is connected to
a separate power source in order to prevent power loss in the event of a power failure.
Troubleshooting
section for more information.
Installing the Cisco NCS 4216
Activating the AC Power Supply
41