Fan assembly for use only with the room heater marked to indicate such use.
installation

FAN INSTALLATION

(120V FAN)
Fan Installation
1. Remove the two screws from the top of the fan housing.
2. Slide the fan up into the rear heat shield.
3. After aligning holes, secure the fan to the rear heat shield using
the two screws removed earlier.
Note: The connection cord should not be in contact with any
hot surfaces.
WARNING: FAN ASSEMBLY MUST BE DISCONNECTED FROM
THE SOURCE OF ELECTRICAL SUPPLY BEFORE
ATTEMPTING THE INSTALLATION.
Neutral
Live
120V AC
60 Hz
Fan Thermodisc
(normally open)
908-126a
22
F1100/F2400/F3100/S2400/F5100/F3500
Manual/
Green
Ground
Auto
Switch
Black
Black
Wiring Diagram
FAN OPERATION
AUTOMATIC
To operate the fan automatically, push the bottom switch on the side
of the fan housing to "AUTO" and the top switch to either "HIGH" or
"LOW" for fan speed.
This will allow the fan to turn on as the stove has come up to operat-
ing temperature. It will also shut the fan system off after the fi re has
gone out and the unit cooled to below a useful heat output range.
If the fan cycles on and off continuously the thermo switch sensor is
not making contact with the stove body. Remove the fan, bend the
bracket closer to the stove and re-install the fan.
MANUAL
To manually operate the fan system push the bottom switch to "MAN"
and the top switch to either "HIGH" or "LOW". This will bypass the
sensing device and allow full control of the fan.
Switching from "AUTO" to "MAN" or "HIGH" to "LOW" may be done
anytime.
WARNING: Electrical Grounding Instructions
This appliance is equipped with a three pronged
(grounding) plug for your protection against shock
hazard and should be plugged directly into a prop-
erly grounded three-prong receptacle. Do not cut or
remove the grounding prong from this plug.
CAUTION: Label all wires prior to disconnec-
tion when servicing controls. Wiring errors
can cause improper and dangerous operation.
Fan
Switch
Black
Fan
Fan
Ground