Installation; Residential Installation; Safety Guidelines And Warnings; Cast Plate Installation - Regency Albany F200B-1 Owners & Installation

Freestanding wood fire
Hide thumbs Also See for Albany F200B-1:
Table of Contents

Advertisement

INSTALLATION

RESIDENTIAL
INSTALLATION
1) Please read this entire manual before you
install and use your new wood fire. Failure
to follow instructions may result in property
damage, bodily injury or even death. Be
aware that local Codes and Regulations may
override some items in this manual. Check
with your local inspector.
2) THE APPLIANCE AND FLUE-SYSTEM
SHALL BE INSTALLED IN ACCORDANCE
WITH AS/NZS 2918:2001 AND THE AP-
PROPRIATE REQUIREMENTS OF THE
RELEVANT BUILDING CODE OR CODES.
APPLIANCES INSTALLED IN ACCORD-
ANCE WITH THIS STANDARD SHALL
COMPLY WITH THE REQUIREMENTS OF
AS/NZS 4013 WHERE REQUIRED BY THE
REGULATORY AUTHORITY.
ANY MODIFICATION OF THE APPLIANCE
THAT HAS NOT BEEN APPROVED IN
WRITING BY THE TESTING AUTHORITY
IS CONSIDERED TO BE IN BREACH OF
THE APPROVAL GRANTED FOR COMPLI-
ANCE WITH AS/NZS 4013.
CAUTION: MIXING OF APPLIANCE OR
FLUE-SYSTEM COMPONENTS FROM
DIFFERENT SOURCES OR MODIFYING
THE DIMENSIONAL SPECIFICATION OF
COMPONENTS MAY RESULT IN HAZ-
ARDOUS CONDITIONS. WHERE SUCH
ACTION IS CONSIDERED, THE MANU-
FACTURER SHOULD BE CONSULTED
IN THE FIRST INSTANCE.
3) Select a position for your Regency Stove.
Consult the minimum clearance chart for
your model and set the stove in place. For
close clearance installation use listed double
wall connector systems.
4) To insure vertical alignment, suspend a plumb
bob from the ceiling over the exact center
of your stove flue and mark a spot on the
ceiling to indicate the center of the chimney.
5) Check that the area above the ceiling is clear
for cutting. Re-confirm the clearance from
the stove to combustibles to insure that they
are within the prescribed limits.
6) Mark the location of the pedestal base on the
floor, then move the stove aside and mark
the position of the floor protector.
7) Install chimney according to chimney manu-
facturers instructions. The performance of
your wood fire is governed to a very large
part by the chimney system. Too short a
chimney can cause difficult start-up, dirty
glass, backsmoking when door is open, and
6
even reduced heat output. Too tall a chimney
may prompt excessive draft which can re-
sult in very short burn times and excessive
heat output.
8) The floor protector must be of non-com-
bustible material. Refer to page 7 for floor
protector clearances.
9) When the floor protection is complete, posi-
tion the stove with the flue collar centered
under the installed chimney.
10) In seismically active areas, Regency recom-
mends that your unit is secured to the floor
by using the bolt down holes inside the
pedestal.
11) Do not connect this unit to a chimney
serving another appliance.
SAFETY GUIDELINES
AND WARNINGS
1) Never use petrol, petrol type lantern fuels,
kerosene, charcoal lighter fuel, or similar
liquids to start or 'freshen up' a fire in your
heater. Keep all such liquids well away from
the heater while it is in use.
2) Keep the door closed during operation and
maintain all seals in good condition.
3) Do not burn any quantities of paper, garbage,
and never burn flammable fluids such as
petrol, naptha or engine oil in your stove.
4) If you have smoke detectors, prevent smoke
spillage as this may set off a false alarm.
5) Do not overfire heater. If the chimney con-
nector, flue baffle or the stove top begin to
glow, you are overfiring. Stop adding fuel and
close the draft control. Overfiring can cause
extensive damage to your stove including
warpage and premature steel corrosion.
Overfiring will void your warranty.
6) Do not permit creosote or soot build-up
in the chimney system. Check and clean
chimney at regular intervals. Failure to do
so can result in a serious chimney fire.
7) Your Regency stove can be very hot. You
may be seriously burned if you touch the
stove while it is operating, keep children,
clothing and furniture away. Warn children
of the burn hazard. For safety reasons a
guard around the fire is recommended.
8) The stove consumes air while operating,
provide adequate ventilation with an air duct
or open a window while the stove is in use.
9) Do not connect this unit to a chimney flue
serving another appliance.
10) Do not use grates or andirons or other
methods for supporting fuel. Burn directly
on the base or bricks where supplied.
11) Open the draft control fully for 10 to 15
seconds prior to slowly opening the door
when refuelling the fire.
12) Do not connect your unit to any air distribu-
tion duct.
13) Your wood fire should burn dry, standard
firewood only. The use of cut timber, ply-
wood, "mill ends", etc. is not allowed as this
fuel can easily overheat your wood fire.
Evidence of excessive overheating will void
your warranty. As well, a large portion of
sawmill waste is chemically treated timber,
which is illegal to burn in many areas. Salt
drift wood and chemically treated fire logs
also must not be burned in your wood fire.
14) No combustible material should be closer
than the clearances, see page 7.
15) DO NOT OPERATE WITH BROKEN
GLASS.
CAST PLATE
INSTALLATION
Install the cast plates by placing the rear cast
plate first and then the side plates ensuring the
cut out sections lock in firmly.
Firebrick
Cast Plate
Regency Albany Freestanding Wood Fire

Advertisement

Table of Contents
loading