Bypass Rod Replacement

If the bypass rod becomes damaged it will need to be replaced.
1. Allow the stove to burn out and cool down, until cool to touch.
2. Open the door and remove the following from inside the unit, smoke deflector, front air tube, baffles
and catalyst. See sections in this manual for details.
Remove smoke
deflector
3. From inside the unit, manoeuver and slightly pull down on the bypass rod to release it from its retain-
ing clip. This could also be removed by hand if reaching up into the catalyst slide and lifting up on
the retaining clip.
tooltip
Catalyst
slide
Bypass rod
4. Slide bypass rod out.
5. Replace with a new bypass rod.
6. Reverse Steps 3 and 2.