2.3
Starting up hardware configuration of PLC CPUs
2.3
General procedure
The hardware configuration for the PLC CPUs used in the NCU7x0, including other
components of the NCU (NCK, CP, HMI, drive), must be defined via STEP 7.
Proceed as follows in STEP7:
1. Create a new project (File, New, Project)
2. Insert, Hardware, SIMATIC 300 station
3. Select the SIMATIC 300 station with the mouse
4. Right-click with the mouse and select Open Object
5. A suitable SINUMERIK component is selected from the "SIMATIC 300\SINUMERIK\840D
6. Add I/O from the STEP7 hardware catalog
Requirements
In order to be able to select SINUMERIK components from the hardware catalog, you must
run the Toolbox setup program first ("Hardware expansions for STEP7" and "Starter"). The
current version of the hardware expansion for STEP7 can also be found under eSupport.
Table 2-1
Hardware expansions
NCU
SINUMERIK 840D NCU
710.1
SINUMERIK 840D NCU
720.1
SINUMERIK 840D NCU
730.1
SINUMERIK 840Di sl with
MCI2
PLC Basic Program Solution Line (P3 sl)
Function Manual, 08/2005 Edition, 6FC5397-0BP10-0BA0
and start HWConfig
sl" hardware catalog.
The addresses for the I/O modules can be modified if required.
MLFB
6FC5 371-0AA00-?AA0
6FC5 372-0AA00-?AA0
6FC5 373-0AA00-?AA0
6FC5 222-0AA02-1AA0
2.3 Starting up hardware configuration of PLC CPUs
Comparable
SIMATIC CPU MLFB
included
6ES7 317-2AJ00-0AB0
6ES7 317-2AJ00-0AB0
6ES7 317-2AJ00-0AB0
6ES7 317-2AJ00-0AB0
Detailed Description
Selection from STEP7 hardware
catalog
NCU710.1
(as of STEP7 V5.3 SP2
and Toolbox 840D sl 01.01.00)
NCU720.1
(as of STEP7 V5.3 SP2
and Toolbox 840D sl 01.01.00)
NCU730.1
(as of STEP7 V5.3 SP2
and Toolbox 840D sl 01.01.00)
840Di with PLC317-2 DP
(as of STEP7 V5.3 SP2
and Toolbox 840D sl 01.02.00)
2-7