Detailed description
2.12 Block descriptions
Description of formal parameters
The table below lists all formal parameters of the PUT function.
Signal
Req
NumVar
Addr1 to Addr8
Unit 1 to Unit 8
Column 1 to Column
8
Line 1 to Line 8
Error
Done
State
SD1 to
SD8
Error identifiers
If it was not possible to execute a job, the failure is indicated by "logic 1" on status parameter
error. The error cause is coded at the block output State:
State
WORD H
1 to 8
0
0
1 to 8
0
0
1 to 8
2-116
I/O
Type
I
Bool
I
Int
I
Any
I
Byte
I
Word
I
Word
Q
Bool
Q
Bool
Q
Word
I/O
Any
Meaning
WORD L
1
Access error
2
Error in job
3
Negative acknowledgment, job
not executable
4
Data areas or data types do
not match or string is empty
6
FIFO full
7
Option not set
8
Incorrect target area (SD)
Value range
1 to 8
(corresponds to use of
Addr1 to Addr8)
[DBName].[VarName]
P#Mm.n BYTE x...
P#DBnr.dbxm.n BYTE x
Note
In high byte number of Var in which
error occurred
Incorrect compilation of Var in a job
Internal error,
try: Check job,
NC Reset
Check data to be written in SD1 to SD8;
in high byte number of the Var in which
error occurred
Job must be repeated since queue is
full
BP parameter "NCKomm" is not set
SD1 to SD8 may not be local data
Function Manual, 08/2005 Edition, 6FC5397-0BP10-0BA0
Remarks
Job start with positive signal edge
Number of variables to be written
Variable identifiers from NC Var
selector
Area address, optional for variable
addressing
Column address, optional for
variable addressing
Line address, optional for variable
addressing
Negative acknowledgment of job or
execution of job impossible
Job successfully executed
See error identifiers
Data to be written