Detailed Description
2.1 NC/PLC interface signals
2.1.3

Alarm signals to PLC

DB10, DBX103.0 (MMC alarm pending)
The HMI component signals that at least one HMI alarm is pending.
DB10, DBX109.6 (ambient temperature alarm)
The ambient temperature or fan monitoring function has responded.
DB10, DBX109.7 (NCK battery alarm)
The battery voltage has dropped below the lower limit value. The control can still be
operated. A control system shutdown or failure of the supply voltage will lead to loss of data.
DB10, DBX109.0 (NCK alarm pending)
The NC signals that at least one NC alarm is pending. The channelspecific interface can be
scanned to see which channels are involved and whether this will cause a processing stop.
DB21, ... DBX36.6 (channelspecific NCK alarm pending)
The NC sends this signal to the PLC to indicate that at least one NC alarm is pending for the
affected channel. See also: DB21, ... DBX36.6 (NCK alarm with processing stop pending)
DB21, ... DBX36.7 (NCK alarm with processing stop present)
The NC sends this signal to the PLC to indicate that at least one NCK alarm, which has
interrupted or aborted the current program run (processing stop), is pending for the affected
channel.
2.1.4
SINUMERIK 840Di-specific interface signals
For a detailed description of the SINUMERIK 840Di-specific interface signals, please refer
to:
References
/HBI/ SINUMERIK 840Di Manual
2-4
Various NC/PLC Interface Signals and Functions (A2)
Function Manual, 08/2005 Edition, 6FC5397-0BP10-0BA0