Cooling Oil at Constant Capacity (%)

Cooling oil at
a constant capacity (%)
With the above operation setting, the Oil Cooling Unit executes cooling operation according to the specified capacity
command (%). Oil temperature control is disabled.
The capacity setting range is 0 to 100%.
∗ The capacity (%) is an approximate index.
∗ When the capacity is set to "0"%, the compressor stops. (The pump and fan are running.)
∗ Even if the capacity command value is same, the actual cooling capacity varies depending on the room temperature and the inlet oil
temperature.
Caution
The oil temperature is not controlled in the operation mode: 9 and the main unit may be seriously damaged, use the product with extra care.
For example, if the cooling capability insufficient status such as 0% operation is caused at the maximum load or the cooling capability
excessive status like 100% operation is caused at low rotation, operating parts (such as the main shaft) may be damaged or burn out, or fire
may be caused in the worst case.
Setting procedure
Operation mode
Operation mode
indicator
display
Factory setting
(With non-standard models, the settings
may be different from the above.)
1·6
Example) Capacity direct designation
(Capacity setting: 100%)
22
Data display
2·4
2·4
3·5
1. Select the operation setting mode.
• Go to the operation setting mode with the
See "Mode changing operation" on page
• The "SETTING" lamp on the operation mode indicator lights.
∗ The number on the operation mode display blinks.
2. Change the operation mode.
When the number on the operation mode display is blinking,
change the number to "9" with the
3. After changing the number, press the
to register it.
After the number is registered, the number on the data display blinks.
∗ "9" on the operation mode display remains lit.
4. Change the set value.
When the number on the data display is blinking, change the set
value to a desired capacity with the
5. After changing the set value, press the
to register it.
After the temperature setting is registered, the number on the
operation mode display blinks.
∗ The number on the data display remains lit.
6. Return to the normal mode.
• Press the
key three times, to return to the normal mode.
See "Mode changing operation" on page
• The "NORMAL" lamp on the operation mode indicator lights.
Operation mode: 9
key.
17
.
or
key.
key
or
key.
key
17
.