Outline of electrical equipment box (Typical)
Protect SW
Short-circuit bar
Over-current Relay
CN2
Transformer box
Customer's wiring
Signal cable insertion hole
Power cable insertion hole
Signal terminal block
9 10 11 12 13 30 31 60 61 62 63 64 65 66 67
Select a terminal according to the main power supply voltage.
For different-voltage model (-047, -048)*
(*Wiring connection example when the voltage is 380V)
• Protect switch (erroneous operation prevention)
The factory default setting of this switch is OFF but some nonstandard units are set to ON.
Pay attention when you attempt to change any of the operation setting, parameter setting or timer setting.
• CN2 (OP2 terminal)
Alarm will be generated on malfunction by connecting an external protecting device and setting the parameter
(n003) (see "Alarm Setting for Optional Protecting Device (Installed by user)" on page
• CN11
Replace this connector with the outlet oil temperature thermistor when you attempt returned oil temperature control.
• CN12
Connect the lead provided in the unit to the optional communication board.
Connection of remote control input
To execute remote control, connect the cable according to the procedure below.
1
Local procurement items
Component
Wiring material
Remove the short-circuit bar (between terminals [10] and [11]) on the terminal block in
2
the electrical equipment box.
(For the crimp tool, use the specified tool.)
Connect the cable specified in
3
∗12 VDC is applied across these terminals (Terminal [10]: negative polarity, [11]: positive polarity).
10
Signal terminal block
Anchor mount
Customer's wiring
9 10 11 13 30 31
12
60 61 62
63
64 65 66
67
Power terminal block
CN12
CN11
Controller board
Our internal wiring
Our internal wiring
U
V
W
047:
380V 400 415 380 400 415 380 400 415
048:
440V 460 480 440 460 480 440 460 480
Single-pole, single-throw remote control switch, or "a" contact that enables operation command output
Note) Select a switch whose minimum allowable load is 12 VDC and 5 mA.
Single-core cable: φ1.2 (AWG16), or twisted cable: 1.25 mm
∗ Recommended Model (Manufacturer): TGN TC-1.25-9T (Nichifu)
1
above between terminals [10] and [11].
Protect SW
Short-circuit bar
9 10 11
12
13 30 31
Over-current Relay
CN2
CN12
Built-in breaker model (-B)
Power terminal block
Terminal screw size and tightening torque
Terminal block for standard model
(Including -C, -H, and -T)
Breaker terminals (-B)
Transformer terminals
(-047, -048)
Earth
2
(AWG16), Bar-type crimp terminal (∗)
APA-1.25N (Daido Solderless Terminal Mfg.)
Signal terminal block
Customer's wiring
60 61 62
63
64 65 66
67
No fuse breaker
CN11
Controller board
(N·m)
0.98
M4
–1.47
2
M5
–3
1.2
M4
–2.0
33
).