Model Identification And Specifications - Daikin AKZ9 Series Instruction Manual

Oilcon; oil cooling unit
Table of Contents

Advertisement

PIM00318A_EN.fm Page 13 Tuesday, October 26, 2010 12:37 PM

Model Identification and Specifications

Specifications (AKZ149 • 329 • 439)
Oil Cooling Unit equivalent horsepower (HP)
Model
∗1
Cooling capacity (50/60 Hz)
Heater
∗2
Power supply
Main circuit
Circuit voltage
Operation circuit
200 V 50 Hz
Max. power consumption
Max. current consumption
200 V 60 Hz
220 V 60 Hz
Transformer capacity
Exterior color
Outer dimensions (H × W × D)
Compressor (Fully-enclosed DC swing type)
Evaporator
Condenser
Propeller fan
Motor
Motor
Oil pump
Discharge rate
Clacking pressure
Temperature
Tuning
Reference
control
type
Control target
(Selectable)
Tuning range
Fixed
Control target
type
Range
Refrigerant control
∗5
Refrigerant (New refrigerant: R410A)
Loading weight
Protection device
Operating range
Room temperature
Inlet oil temperature
Oil viscosity
Discharge
External
pressure loss
Suction
Applicable oil
Connection pipe
Oil inlet
Oil outlet
Oil drain
Sound level (Measured at 1 m from front of unit,
at 1 m height, in anechoic room)
Transportation vibration resistance
Weight
Internal circuit breaker (Rated current)
Oil tank (Volume)
Local procurement item Circuit breaker (Rated current)
Model identification
AKZ
Series name AKZ: Energy-saving high-precision
Note) ∗1: Cooling capacity is the value at standard point (inlet oil temperature and room temperature: 35˚C, ISO VG32 oil). The product tolerance is approx. ±5%.
∗2: Be sure to use a commercial power supply. Using an inverter power supply may result in burnout. Voltage fluctuation range should be
within ±10%. If voltage fluctuation exceeds ±10%, consult DAIKIN.
∗3: For the different-voltage model, three types (–046, –047 and –048) –047 and –048 is equipped with transformer. (–046 is without
transformer. The outer dimension and weight is the same as standard model.)
∗4: The optional machine temperature tuning thermistor is required. (For details, see page
∗5: The "–C" model is supplied with MSDS (Material Safety Data Sheet) for refrigerant R410A.
∗6. Electric unit protective structure: IP54 or equivalent (Use conduits higher than IP54 for the knock out hole)
∗7. Performance for transportation vibration refers to the performance of standard units.
∗8. No line breaker is included in this product. It must be separately provided by the customer.
∗9. The yellow line on the tank oil level gauge shows the highest oil level, and the red line shows the lowest oil level.
∗10.For energy-saving purposes, the rotation speed of a fan will vary according to the room temperature.
This may change its noise level as well, but it does not constitute a failure.
0.5
AKZ149
∗9
Stand-
–C
–B
–H
–T
Different-voltage
ard
kW
1.3/1.4
kW
1
3-phase 200/200 · 220 VAC 50/60 Hz
0.90kW/3.9A
1.29kW/4.1A
0.90kW/3.9A
0.91kW/3.6A
1.32kW/4.2A
0.91kW/3.6A
0.91kW/3.5A
1.43kW/4.2A
0.91kW/3.5A
2.6 kVA
mm
650 × 360 × 440
950 × 360 × 440
810 × 360 × 465 950 × 360 × 440
Equivalent to 0.4 kW
φ250, 54 W
L/min
12/14.4
MPa
0.5
Room temperature or machine temperature
Inlet oil temperature or outlet oil temperature (Factory setting: Inlet oil temperature)
K
Within ±9.9 relative to reference temperature (Factory setting: 0.0)
˚C
Inverter compressor rotation speed + Electronic expansion valve opening
kg
0.49
Over-current relay (Pump motor), Reverse-phase protector, Restart prevention timer, Low room temperature protection thermostat,
High oil temperature protection thermostat, Low oil temperature protection thermostat, Pump relief valve, Discharge pipe temperature
thermostat, Condenser temperature thermostat, Refrigerant leak detector, Inverter protector, High-pressure pressure switch ("–C" only),
Compressor protection thermostat ("–C" only), Overheat prevention temperature thermostat ("–H" only), Oil lack prevention switch ("–H" only) No fuse breaker (-B only)
˚C
˚C
2
mm
/s
Lubrication oil, Mineral hydraulic oil (Phosphoric ester hydraulic oil, water/water-soluble liquid, chemical, food, fuel, cutting/grinding fluid cannot be used.)
Rc3/4
Rc1 1/4
dB (A)
kg
51
78
68
A
10
L
15
∗8
A
9 -
Menu symbol (Note 1)
or Numbering symbol
Distinction symbol
Series symbol (9 series)
Nominal cooling capacity (Note 2)
inverter oil cooling unit
1.2
AKZ329
∗3
∗9
Stand-
–B
–C
–H
–T
Different-voltage
ard
2.8/3.2
1
∗3
3-phase 200/200 · 220 VAC 50/60 Hz
3-phase 200/200 · 220 VAC 50/60 Hz
12/24 VDC
1.36kW/4.9A
1.49kW/4.8A
1.36kW/4.9A
1.43kW/4.8A
1.61kW/5.2A
1.43kW/4.8A
1.43kW/4.6A
1.72kW/5.0A
1.43kW/4.6A
2.6 kVA
Ivoly White
775 × 360 × 440
1075 × 360 × 440
965 × 360 × 465 1075 × 360 × 440
Equivalent to 0.75 kW
Shell & coil type
Cross fin coil type
0.4 kW × 4P
∗4
(Factory setting: Room temperature: Mode 3)
Inlet oil temperature or outlet oil temperature
5–50
0.72
5–45
5–50
1.4–200 (ISO VG2–32)
0.5 MPa or less
Within –30.7 kPa
Rc3/4
Rc3/4
Rc1 1/4
Rc3/4
Rc1/4 (Fastened with plug)
∗10
62
2
Vertical: 14.7 m/s
(1.5 G) × 2.5 hr (10 to 100 Hz sweep/5 min)
87
56
83
73
92
10
20
10 (Required for the models other than "–B")
(Note 1) Menu symbol
• B : Circuit breaker (with built-in breaker)
• C : CE-conformable
• H : Built-in heater
• T : Built-in tank
• Different-voltage (Built-in transformer)
046 : 220 VAC, 230 VAC
047 : 380 VAC, 400 VAC, 415 VAC
048 : 440 VAC, 460 VAC, 480 VAC
(Note 2) Nominal cooling capacity
Indicates cooling capacity at standard point with commercial
power supply frequency of 60 Hz. (Inlet oil temperature and
room temperature: 35˚C, VG32-equivalent oil is used.)
• 14 : 1.4 kW
• 32 : 3.2 kW
• 43 : 4.3 kW
34
.)
Compliant with
ROHS
1.5
AKZ439
∗3
∗9
Stand-
–B
–C
–H
–T
Different-voltage
ard
3.8/4.3
1
∗3
∗3
3-phase 200/200 · 220 VAC 50/60 Hz
1.80 kW/6.6 A
1.88 kW/6.4 A
1.88 kW/6.1 A
2.6 kVA
875 × 360 × 440
1175 × 360 × 440
1065 × 360 × 465 1175 × 360 × 440
Equivalent to 1.1 kW
φ300, 54 W
24/28.8
0.6
0.98
Rc1 1/4
Rc3/4
∗10
65
64
91
81
100
10
20
50/60 Hz
50/60 Hz
50/60 Hz
∗3
13