Adjustments; Introduction; Example; Sensors And Daylight - Kodak Miniloader 2000 Service Manual

Table of Contents

Advertisement

SM 3477

3. ADJUSTMENTS

INTRODUCTION

In this section it is frequently explained how to use the CES SERVICE SOFTWARE. The first
line tells always what should be performed. In the next lines it is explained how to reach this
goal. These additional explanations are printed italic and can be skipped if you are
experienced with the CES SERVICE SOFTWARE.

EXAMPLE:

1
.
Start the CASSETTE INPUT FLAP MOTOR M1
Start the SERVICE PROGRAM.
Select SERVICE MODE from the GLOBAL MENU .......................... press ENTER
ENTER SERVICE MODE MESSAGE is displayed ............................ press ENTER
UNIT DATA are displayed....................................................................... press ENTER
Select COMPONENT TEST from the MAIN MENU ........................ press ENTER
Select CASSETTE MOTORS ................................................................... press ENTER
Select INPUT FLAP MOT M1 ................................................................ press ENTER
Select CLOSE/OPEN ................................................................................. press ENTER

SENSORS and DAYLIGHT

The SENSORS are sensitive to daylight and to room light. This can result in wrong
measurements when you do an adjustment, or a SENSOR becomes triggered and the
ML2000 (ML2000 P) tries to bring the various units to HOME POSITION. For this reason dim
the light or cover the SENSORS when you do the adjustments. This is especially important
when you measure the output voltage of a SENSOR.

CASSETTE AREA

INPUT FLAP

PURPOSE:
This adjustment ensures that the INPUT FLAP is closed light-tight when a CASSETTE is fed
into the ML2000 (ML2000 P).
1
.
Take off the PANEL.
2
.
Take off the FRONT PANEL with the DISPLAY.
3
.
Close the INPUT FLAP.
Start the SERVICE PROGRAM
Select SERVICE MODE from the GLOBAL MENU .......................... press ENTER
ENTER SERVICE MODE MESSAGE is displayed ............................ press ENTER
Select COMPONENT TEST from the MAIN MENU ........................ press ENTER
Select CASSETTE MOTORS ................................................................... press ENTER
Select CASSETTE INPUT FLAP M1..................................................... press ENTER
Select CLOSE
4
.
Adjust SENSOR B4/C_IF_EC INPUT FLAP CLOSED until the INPUT FLAP is fully
closed.
KODAK AG, Stuttgart
3-1
ADJUSTMENTS
6/97

Advertisement

Table of Contents
loading

This manual is also suitable for:

Miniloader 2000 p

Table of Contents