000
105
7. Appendix

Error/Warning Indications

If a warning, caution, or operating condition that requires confirmation occurs on the unit, a message is
displayed on the sub display, the REC lamp starts flashing, and a warning sound is emitted.
The buzzer is output to the built-in speaker or to the headphones connected via the headphone
connector.
When the unit is turned on, a message appears on the sub display screen prompting you to execute APR
if the auto adjustment for the image sensor (APR) has not been performed for a certain period of time. In
this case, follow the on-screen instructions to execute APR (page 70).
Error Display
The unit will stop operation when the following kind of display occurs.
Error display
Buzzer
indication
E + Error code
Intermittent High-speed
Warning Display
When one of the following messages occurs, use the following table to resolve the problem.
Warning display
Buzzer
indication
Media Full
Continuous High-speed
1)
Battery End
Continuous High-speed
1)
Temperature High
1)
Intermittent Flashing
REC lamp
Cause and Solution
The unit may be defective. Recording stops even if
REC is displayed on the viewfinder/monitor screen.
flashing
Turn off the power and check the connected
equipment, cables, and media. If the error persists
when the unit is turned on again, contact your Sony
service representative. (If power cannot be turned off
by setting the power switch to OFF, remove the
battery pack or the DC IN source.)
REC lamp
Cause and Solution
Clips could not be recorded, copied, or split because
flashing
there is no remaining capacity on the SxS memory
card.
Replace immediately.
The battery pack is dead. Recording is disabled.
flashing
Stop operation and recharge the battery pack.
The internal temperature is high.
Turn off the unit and allow it to cool down before
operating it again.
Warning display
Buzzer
REC lamp
indication
Insufficient Voltage
1)
Continuous High-speed
flashing
EXT. I/F Signal Error
Intermittent High-speed
flashing
AXS Firmware
Continuous High-speed
Mismatch
flashing
AXS Recorder Temp.
Intermittent High-speed
High
1)
flashing
Lens Signal Error
Message is not displayed on the monitor screen.
1)
About temperature warnings
The Temperature High and AXS Recorder Temp High warnings may be displayed when operating
within the guaranteed operating temperature of the unit, depending on the operating mode and
usage environment. Recording does not immediately stop when these messages are displayed, but the
suggestions given in the Cause and Solution column of the table should be implemented promptly.
Caution and Operation Confirmation Display
The following caution and operation confirmation messages may appear on the monitor screen or sub
display, and warning icons may be displayed and messages displayed in the Info category > Camera
Condition in the menu. Follow the instructions provided to resolve the issue.
Display indication
Battery Error
Please Change Battery
Backup Battery End
Please Change
Cannot Use SxS(A)*
Please Change
Cause and Solution
The DC IN voltage is too low. Recording is disabled.
Connect another power source.
An error was detected with the signal on the
mounting terminal for an expansion unit.
Check the connection to the AXS-R7 or other device.
The AXS-R7 cannot be operated correctly.
Update the firmware version of the AXS-R7.
The internal temperature of the AXS-R7 is high.
Turn off the unit and allow it to cool down before
operating it again.
An error was detected with the signal on the
mounting terminal for an expansion unit.
Check the connection to the lens or other device.
Cause and Solution
An error was detected in the battery pack.
Replace with a normal battery pack.
The remaining capacity of the backup battery is
insufficient.
Replace the backup battery.
A memory card that has been partitioned or a
memory card containing more clips that can be
handled by the unit was inserted.
The card cannot be used in the unit, and must be
replaced.

Advertisement